background image

 

 

 Model UH-2C 

 

Note about Twisted-Pair Cables 

The UH-2C is designed for operation with standard Cat6 cables (TIA/EIA 568B wiring). You 
can use Cat5e cables also if the distance between sender and receiver is 70 ft or less. 
Shielded Cat6 can also be used; in fact, shielded Cat6 offers the best performance and 
provides immunity to external noise if the installation is in an electrically noisy environment. 
Avoid using Zero-skew or low skew cables. The low skew cables work well for analog video 
extension over twisted pair, but since the UH-2C is a pure digital system, the cross-talk of 
the low skew cables will actually shorten the maximum achievable cable length

 

3. Troubleshooting 

There are no field serviceable parts or circuits in the device. If you think that the device is 
malfunctioning, please first try the following steps: 

 

Check to make sure you haven’t crossed the 2 Cat6 cables 

 

Check the video connections 

 

Unplug the power supply and re-attach it 

 

Connect the display directly to the source and make sure you can get a picture without the 
extender. If so then using the menus of the video source try to set the output resolution to 
a low one (such as 480p) to start with. Insert the extender and verify that you get an 
image, if so; then set the resolution to the next higher value (such as 720p). Continue this 
process until you get the highest possible resolution without loss of image or audio.  

 

The quality of the cable and the connections

 will determine the maximum length and 

resolution achievable.  Certain types of cable may be able to show the video, but the audio 
will not be heard.

 

 
3.1 Contacting Hall Research 

If you determine that your extender is malfunctioning, do not attempt to repair the unit. The unit 
contains no user serviceable equipment. Opening the unit will void the warranty. Contact the Hall 
Research Technical Support department at 714-641-6607 to obtain a RMA (Return Authorization) 
number. 
Before you do, make a record of the history of the problem. We will be able to provide more 
efficient and accurate assistance if you have a complete description. 

 

3.2 Shipping and Packaging 

If you need to transport or ship your extender: 

• Package it carefully. We recommend that you use the original container. 
• Before you ship the units back to Hall Research for repair or return, contact us to get a 

Return Authorization (RMA) number. 