Page 1: ...AERATION SYSTEM Owner s Manual Models OXK 2035 OXK 4500 OXK 7000 OXK 8500 OXK 1 100 OXK 1410 ...

Page 2: ...fficient and whisper quiet OX Gen delivers high aeration performance to create and maintain a healthy pond environment OX Gen aeration enhances pond oxygen levels by circulating the water These pumps can be used year round by regulating oxygen levels in the summer and keeping a hole in the icy water during the winter OX Gen Aeration Systems are safe to use in both indoor and outdoor environments P...

Page 3: ...y Hz Input Voltage V Rated Power W Output CFM Specs Pg 3 OX Gen Aeration Air Pump Kit Parts Included 8 Diffuser Disc 3 8 Weighted Vinyl Tubing Model Barbed T Fitting Hose Clamp Manifold Valve Pipe Connector OX 3500 1 20 x x 1 2 OX 4500 2 25 2 1 1 2 OX 7000 2 30 2 1 1 2 OX 8500 3 75 1 3 Way x 1 3 OX 1100 4 80 1 4 Way x 1 4 OX 1410 4 80 1 4 Way x 1 4 ...

Page 4: ...ed in water before connecting your LifeLine Air Pump Disconnect the power supply to pump before performing any maintenance procedures Do not operate pump with defective membrane membranes Do not place air pump in water Pump surfaces become very hot during operation allow surfaces to cool before handling Do not place air pump in water The safety of you and others is extremely important Failure to f...

Page 5: ...ck your pump before using it again Carefully examine the appliance after installation if the supply cord is damaged it must be replaced by a qualified technician in order to avoid hazard Do not carry pump by the power supply cord Disconnect the plug when not in use and before performing maintenance The unit is to be supplied through a residual current device RCD having a rated residual operating c...

Page 6: ...Disc B B C 1 C 1 C 2 C 2 C 3 C C A A D D D D 3 D 2 D 1 F 1 G G G F 2 E Note Pliers will be needed for cutting tubing and tightening clamps tools not included Use letter chart below as a guide to connect your OX Gen Air Pump For OX 4500 and OX 7000 systems begin by cutting 3 3 pieces of tubing Connect as shown OX 3500 OX 4500 and OX 7000 Pg 6 OX Gen Aeration ...

Page 7: ...2 C C C C C C E 2 E 2 A A D D D D D D D 7 D 3 D 3 D 5 D D 4 D 4 D 2 D 2 D 1 D 1 D 6 F 1 F 1 G G G G G F 2 F 2 F 3 F F E 1 E 1 E 3 OX 1 100 and OX 1410 OX 8500 B C 1 C 2 A D D D G G G G F D D B C 1 C 2 A D D D G G G G F D D Connect as shown ...

Page 8: ... Gen Aeration Pump Note Never install or operate the pump in the vicinity of highly flammable or explosive materials Interval operation When the pump is powered off for several hours in intervals condensation can form from the inside of the unit Store pump in a dry closed room at room temperature to help prevent condensation from happening Place the diffuser discs in different locations under wate...

Page 9: ... after creating an air divider Ensure all tubing is tightly secured when installing your OX Gen Aeration System Note Avoid Sharp bends when laying out your weighted tubing with diffuser discs attached Discs will work effectively down to 10 feet Old or dirty diffuser discs will reduce aeration capacity Make sure to follow maintenance procedures periodically to prevent build up from pump s airway En...

Page 10: ...tion it can remain in place at freezing temperatures Otherwise store unit indoors in a dry room room temperature Manifold Valves Manifold Valves allow you to provide air to multiple diffuser discs in different locations around the pond with a single air pump These valves come in a barb width They allow you to turn the air on and off plus they allow you to control the air pressure to each diffuser ...

Page 11: ...ch Remove diaphragm socket Insert new diaphragm s Reassemble the unit in the reverse order see figure 3 below Air Pump Diaphragm Replacement Instructions Please note a temperature above 104 F can cause the diaphragm in your pump to fail Never operate the unit with defective diaphragms Always replace the complete pair even if one diaphragm is defective Failure to follow these instructions can resul...

Page 12: ...re to unplug the pump first before cleaning and maintenance 2 Remove the filter sponge from the air inlet Remove any dust or foreign matter from the air inlet the filter cover and the filter sponge mounting surface If the sponge is heavily soiled you can use a neutral detergent to wash the old sponge down Remember to rinse it well with water completely and dry it in the sun before reinstalling Pg ...

Page 13: ...gulating valves The diffuser discs are dirty Clean the diffuser discs The air filter is dirty Replace air filter Diaphragm defective Replace diaphragm Pump is unusually loud Valve unit or diaphragm defective Replace valve unit or diaphragm 2 1 3 4 5 Pg 13 OX Gen Aeration Note We recommend cleaning diffuser discs a few times throughout the year No bubbles coming out of diffuser disc discs 1 Tubing ...

Page 14: ... will be accepted if received more than 30 days after the term of the warranty Correction of defects in the manner and for the duration of the warranty described in this warranty shall constitute complete fulfillment of all liabilities and responsibilities of HOP to the user with respect to the product and shall constitute full satisfaction of all claims whether based on contract negligence strict...

Page 15: ...Pg 15 OX Gen Aeration NOTES ...

Page 16: ...ce team is available to help you through the entire project from selection installation through ongoing care maintenance Please feel free to call us for design build tips product advice and technical assistance 1004 Liberty Industrial Drive O Fallon MO 63366 1 866 831 6558 www halfoffponds com Visit us at www halfoffponds com Set up a Customer Account Use code HOP10OFF in Cart Save 10 on your enti...