9 Mechanical Specifications HALscan 10X20
Dimensions:
W x H x D: 120 x 95 x 96 mm
Size (without lens ring)
W x H x D: 120 x 122 x 96 mm
Size (with lens ring)
Drawing Beam Entrance Side
Drawing Beam Exit Side
13
Page 1: ...HALscan X20 XY3 100 Scanheads Users Manual 2020 2022 by HALaser Systems 1...
Page 2: ...e Code 7 5 Features and Technical Data 8 6 Functional Description 10 7 Electrical Connection 11 8 Initial Operation 12 9 Mechanical Specifications HALscan 10X20 13 10 Mechanical Specifications HALscan...
Page 3: ...hout prior notice The given technical data base on specifications of the vendor of components or parts of the hardware Tolerances are to be expected Duplication of this manual in whole or in part or r...
Page 4: ...of HALscan 16X20 added 07 2022 Added missing backchannel description in pinout 07 2021 Naming scheme explanation added 06 2021 XY3 100 certified logo added 10 2020 Resolution value in technical data c...
Page 5: ...tput it again It can t block or weaken the laser beam To prevent unwanted emission of the laser beam above a particular danger class the laser device must be fitted with a shutter or any other suitabl...
Page 6: ...he mirrors and galvos from dust and humidity Furthermore there should be no larger vibrations and it has to be ensured nobody and nothing can touch the mirrors or the galvos Corrosive and or wet and o...
Page 7: ...ourself with the content of this manual before using such a scanhead for the first time Furthermore this manual must be accessible to anyone who will be involved in developing installing or using a la...
Page 8: ...7 W 10 W Mirror size 10 mm 16 mm 20 mm 30 mm Maximum Laser Power 50 W 2 90 W 2 3 200 W 10600 nm CO2 300 W 1064 nm 2 600 W 1064 nm CW 2 300 W 10600 nm CO2 1 kW 1064 nm 2 400 W 10600 nm CO2 2k W 1064 nm...
Page 9: ...nting points of the mirrors this would lead to damage of the scanhead together with a loss of any kind of warranty Depending on used pulses and frequency additional cooling of the head may be necessar...
Page 10: ...Independent from that the user is still free to make use of correction files in order to get specific shapes of the output or to gain an additional level of accuracy for special applications The HALs...
Page 11: ...2 15 V 13 15 V 14 A 15 B 16 C 17 D 19 F 22 15 V 23 GND 24 GND 25 15 V The power supply needs to be a balanced 15 V 0 5 V tolerance ATTENTION When the scanhead is powered separately power has to be fed...
Page 12: ...tion where it may start up in the middle of an already running data transmission This may lead to the first valid position command received is at an extreme and unexpected position In such a situation...
Page 13: ...Mechanical Specifications HALscan 10X20 Dimensions W x H x D 120 x 95 x 96 mm Size without lens ring W x H x D 120 x 122 x 96 mm Size with lens ring Drawing Beam Entrance Side Drawing Beam Exit Side 1...
Page 14: ...Mechanical Specifications HALscan 16X20 Dimensions W x H x D 156 x 121 x 115 mm Size without lens ring and without optional water cooling connection Drawing Beam Entrance Side Drawing Beam Exit Side 1...
Page 15: ...11Mechanical Specifications HALscan 20X20 Dimensions W x H x D 169 x 148 x 120 mm Size Drawing Beam Entrance Side Drawing Beam Exit Side 15...
Page 16: ...12Mechanical Specifications HALscan 30X20 Dimensions W x H x D 185 x 148 x 140 mm Size Drawing Beam Entrance Side Drawing Beam Exit Side 16...
Page 17: ...03D 11 F F Theta 10 H Humidity 6 L Linear 10 M Maximum Laser Power 8 Mirror size 8 P Power supply 8 11 R Resolution 8 S Scale drift 8 Scanning angle 8 T Temperature 9 V Vibrations 6 W Water cooling 9...
Page 18: ...18...