III. Warranty 

 

Hal Technology provides a one-year limited warranty of the Model HFX205 Handheld 

formaldehyde meter, but not including necessary calibration service.   

 

Warranty begins from shipping date. 

 

The user is responsible for the cost of shipping in the case of any service or repair 

needed. 

 

The warrantee only limits to the HFX205 and HAL TECHNOLOGY does not extend 

this liability to accessories and any other equipment damage, body injury and loss 

of properties due to abnormal use. 

The following are not included in the warranty:   

 

Improper connection to a power source, resulting in damage of the instrument.

 

 

Any physical damage due to mechanical forces (e.g., collision or dropping) that may 

cause any damage of the front panel, LCD screen, switch and internal components, 

etc.

 

 

Unauthorized opening of the instrument.

 

 

Damage due to operation in an un-specified environmental condition.

 

 

Abnormal operation due to instrument needing calibration.

 

 

Limitation of Warranty 

A. Hal Technology warrants that all equipment shall be free from defects in material and 

workmanship  under  normal  use  for  a  period  of  one  year  from  date  of  shipment  to  Buyer 

except that Hal Technology does not warrant that operation of the software will be completely 

uninterrupted  or  error  free  or  that  all  program  errors  will  be  corrected.  Buyer  shall  be 

responsible for determining that the equipment is suitable for Buyer’s use and that such use 

complies with any  applicable local,  state,  or federal  law.  Provided that  Buyer  notifies Hal 

Technology in writing of any claimed defect in the equipment immediately upon discovery 

and any such equipment is returned to the original shipping point, transportation charges 

prepaid,  within  one  year  from  date  of  shipment  to  Buyer  and  upon  examination  Hal 

Summary of Contents for HFX205

Page 1: ...L HFX205 Handheld Formaldehyde Meter Monitor Operational Manual 7970 Cherry Avenue Suite 303 Fontana CA 92336 USA Phone 855 438 4258 toll free Fax 866 402 9190 toll free Info haltechnologies com http...

Page 2: ...Page 2 of 24 V2 0 This Page intentionally left as blank...

Page 3: ...eatures 8 1 2 Specifications 8 1 3 Sensor cross sensitivity data 9 II Basic Operation 10 2 1 Measuring Screen 10 2 1 1 Detailed Screen Description 11 2 2 Browsing Screen 13 2 3 Setting Screen 15 2 3 1...

Page 4: ...e 4 of 24 V2 0 Version Table Date Version Comment May 22 2015 2 0 User Interface Redesigned February 1 2014 1 2 Window 7 8 Compatible Upgrade May 3 2012 1 1 Final Release May 18 2010 1 0 Initial Relea...

Page 5: ...t any time without notice or obligation Published in the United States of America Copyright 2015 by Hal Technology All rights reserved No part of the contents of this manual may be reproduced transmit...

Page 6: ...wing situations DO NOT expose to combustible explosive environments DO NOT expose to environments where rust or radioactivity are present DO NOT expose to an environment exceeding the specified limits...

Page 7: ...on time Low power design allows long operation time Exceptional linearity and stability allow easy and very long intervals between calibration checks The external digital temperature and humidity sens...

Page 8: ...erature and humility sensor probe options Temperature compensated reading option Live data streaming and TWA STEL measurement capabilities through USB Excess limit warning user defined Window XP 7 8 c...

Page 9: ...Less than 240 grams Environmental Condition Operating 0 40 C 15 90 RH Storage 20 50 C 90 RH Standard accessories AC charger USB cable CD with data download software and user manual Optional accessori...

Page 10: ...screen or item ENTER Confirm the current selection enter a parameter or save the current sampling value BACK Change the concentration unit while the unit is measuring or return from the current selec...

Page 11: ...STOP key to stop measuring The instrument will automatically shut off after 5 minutes of inactivity unless the unit is sampling 2 1 1 Detailed Screen Description Figure 1 Annotated measure screen of t...

Page 12: ...the alarm were turned off an X would appear next to the alarm icon Battery Status The battery indicator displays the battery s remaining charge graphically Three bars represent 100 of charge in the b...

Page 13: ...ure sensor probe to function If no probe is installed the unit will display hPa Time Current time set by a user is displayed Date Current date set by a user is displayed By default the backlight will...

Page 14: ...number of records e g 253 253 In Figure 2 the user is viewing record number 253 of a total 253 records Delete a Record Press the UP or DOWN key to select the record to be deleted and press the ENTER...

Page 15: ...creen An arrow will appear as in Figure 4 Use the UP and DOWN buttons to scroll through the different settings Scroll to the desired setting and press the ENTER button to select that parameter A new s...

Page 16: ...have made press the ENTER button When completed press the BACK button to exit the date setting screen Sample Interval The sample interval parameter can be set to either take a sample every n minutes w...

Page 17: ...ound This options allows the user to set the keypad sound options Neither the alarm indicator nor the power up sounds will be affected by this setting To modify the button sounds option go into the so...

Page 18: ...ast setting screen and press the ENTER button The currently selected option will have a blinking underscore beneath it and using the UP and DOWN buttons will change the option between 1 and 9 To cance...

Page 19: ...Y values in the second column represent the response of the sensor to be calibrated The values in the third column are the calibration coefficients An example calibration procedure is described below...

Page 20: ...N STOP button to start sampling Wait for Y value to stabilize and then press the RUN STOP button again 8 After finishing both samplings move the cursor back to the first row Press and hold the ENTER b...

Page 21: ...c Unauthorized opening of the instrument Damage due to operation in an un specified environmental condition Abnormal operation due to instrument needing calibration Limitation of Warranty A Hal Techno...

Page 22: ...to pay when due any portion of the purchase price or any other payment required from Buyer to Hal Technology under this contract or otherwise all warranties and remedies granted under this Section ma...

Page 23: ...n site at buyer s facility by a Hal Technology authorized employee Buyer pays shipping costs to factory seller will pay standard return shipping costs during the warranty period Buyers may select a fa...

Page 24: ...information to the email address below services haltechnologies com User Registration Form Company _____ Contact Person ______________ Address ______ ______ __ City ____State Province Country _____ Po...

Reviews: