11
12
●
Selecting Simulation Mode
When you select Simulation Mode, you will enter Simulation Mode with the Simulation Mode Standby
screen shown. If the HAKKO FU-500 receives a Start signal when this screen is displayed,
it will behave in the same manner as in Auto Mode but the motor will not start (no solder will be fed).
Note that no solder feed or iron control error will be detected.
Simulation Mode
Standby
Start signal
received
Simulation Mode
PS 00
Primary Feed
●
Selecting Test Operation Mode
When you select Test Operation Mode, you will enter Test Operation Mode.
In this mode, the HAKKO FU-500 will start to operate in PS (point soldering) mode for operation check
or adjustment after selecting a program number.
The HAKKO FU-500 outputs the same signal to the robot as the output signal in Auto Mode.
All input signals from the robot will be ignored, but any solder feed error will be detected
and displayed.
Test Operation
Test Operation
PS 00
Primary Feed
Select
program No.
START
Operation completed
Select SET PRG NUM
※ Tens place -> Units place -> Confirm
●
Selecting Auto Mode
When you select Auto Mode, you will return to the Auto Mode Standby screen.
If the HAKKO FU-500 receives a Start signal when this screen is displayed,
it will start to operate for Auto Mode.
Auto Mode
Standby
Start signal
received
Auto Mode
PS 00
Primary Feed
Turn on the power switch of HAKKO FU-500.
The start-up screen will be displayed, and then move to Auto Mode Standby screen.
If the HAKKO FU-500 receives a Start signal when this screen is displayed, it will start to operate
for Auto Mode.
If the HAKKO FU-500 does not receive a Start signal and the control button is pressed,
it will show the Mode Select screen.
To change the value or the cursor position, turn the control knob and then press the knob to confirm.
Auto Mode
Standby
Control
button
Mode Select
Changing the settings
(3 lines are displayed at a time.)
Auto Mode
SimulationMode
Test Operation
Solder Feed
Program Set
Parameter Set
Log View
Select
Program Number
0
0
START
SET PRG NUM
Exit
FEEDER CONTROLLER
3) Uploading the HAKKO FU-601 tip temperature
The PC I/F reads in the iron tip temperature from the HAKKO FU-601 and uploads it to the PC.
4) Uploading the operation log
The PC I/F uploads the total number of soldering points and the total amount of fed solder to the PC.
5) Clearing the operation log.
The PC I/F clears the operation log.
The PC I/F does not operate while the feeder is run except for uploading of the tip temperature.
The display for uploading of the tip temperature is not updated while the feeder is run.
For more information about how to use, see the HAKKO FU-500 PC Link Software Instruction Manual.
The PC Link Software can be downloaded from the HAKKO Document Portal after user registration.
FU-500
ESD
SAFE