background image

8

DS (Drag Soldering) Mode

Drag soldering process

When selecting a program number, set the signal P7 (MSB) to 1. 

The controller outputs either the status signal Form1 or Form2

   (according to the setting made during program setting). 

Program selection setup time : t

 

ps 

 5msec

Program selection hold time : t

 

ph 

 25msec

Start signal pulse width : t

 

sw 

 25msec

Iron move signal pulse width : t

 

msw 

 25msec

Iron stop signal pulse width : t

 

mew 

 25msec

Program No. (In)

Start solder feed (In)

Controller ready (Out)

Primary feed (Internal)

Primary back feed (Internal)

Unit down command (Out)

Upper limit detection (In)

Lower limit detection (In)

Primary heating (Internal)

Start continuous feed (Out)

End continuous feed (In)

Secondary feed (Internal)

Secondary back feed (Internal)

Secondary heating (Internal)

Tertiary feed (Internal)

Tertiary back feed (Internal)

Tertiary heating (Internal)

Status signal

Form1 (Out)

Status signal

Form2 (Out)

15

Selecting Parameter Set

When you select Parameter Set, you will enter Parameter Setting mode.

In this mode, you can specify the operation of the entire system. 

1. Feed Speed (Specifying the feed speed in continuous feed mode)

0.1 

-

 99.9mm / sec

2. S-U Mode (Selecting a slide unit connection mode)

Internal (Int) or External (Ext)

When Internal Mode is selected, all upper/lower limit

detection signals from the robot will be ignored.

3. S-U Timeout (Specifying the slide unit upper/lower limit detection timeout)

-

 99 sec

Parameter Set

Feed Speed

S-U Mode

S-U Timeout

Iron Connect

Iron Status

Exit

10.0

Int

30

Con

Rdy

Feed Speed

1

0.0mm / sec

Slide Unit

Connect Mode

Int Mode

Ext Mode

Slide Unit

Time - out

3

0 sec

t

 

ps

t

 

ph

t

 

sw

t

 

msw

t

 

mew

On

Off

On

On

On

On

On

Off

Off

Off

Off

Off

Run

Summary of Contents for FU-500

Page 1: ...saka 556 0024 JAPAN TEL 81 6 6561 3225 FAX 81 6 6561 8466 http www hakko com E mail sales hakko com 23 Part No BX1000 BX1001 BX1002 BX1003 BX1004 BX1005 BX1006 Part No BX1007 BX1008 BX1009 Part No BX1...

Page 2: ...in the table below Before changing the solder diameter see How to change the solder diameter on page 17 Solder diameter mm 0 3 0 5 0 6 0 65 0 8 1 0 1 2 1 6 Up to 1kg bobbin of solder can be used Feede...

Page 3: ...nings and cautions are placed at critical points in this manual to direct the operator s attention to significant items They are defined as follows WARNING Failure to comply with a WARNING may result...

Page 4: ...immediately stop the feed and show this error message on the LCD along with buzzer sound When a hardware error is detected the HAKKO FU 500 will immediately stop the feed and show this error message o...

Page 5: ...KO FU 601 ready input is Not Ready during Auto Mode or Manual Program Mode This error will not occur in Adjustment Mode or Continuous Feed Mode If the HAKKO FU 601 ready input is Not Ready before Auto...

Page 6: ...screws described in this manual The attachment of the solder feed pulley unit for 0 3mm BX1000 is different Refer to the How to set solder in the BX1000 Please be careful not to tighten the screw too...

Page 7: ...d guide nozzle Loosening the adjustment screw will allow you to move the entire solder feed guide set as shown in the figure below Move the solder feed guide set to the tip Loosening the adjustment sc...

Page 8: ...Tertiary heating Internal Status signal Form1 Out Status signal Form2 Out Run 16 4 Iron Connect Connection status to the HAKKO FU 601 Connection or Disconnection When Not Connect is selected preset s...

Page 9: ...ternal Secondary heating Internal Tertiary feed Internal Tertiary back feed Internal Tertiary heating Internal Status signal Form1 Out Status signal Form2 Out 15 Selecting Parameter Set When you selec...

Page 10: ...Feed Speed 3 Back Feed 3 Back Speed 3 Heat Time 3 Preset Status Sig Primary Feed Length Primary Feed Speed Primary Back Feed Length Primary Back Speed Primary Heat Time Secondary Feed Length Secondar...

Page 11: ...than Exit Tens place Units place Confirm Tens place Units place One decimal place Confirm For feed amount or feed speed tens place units place one decimal place For heating time units place one decim...

Page 12: ...ceived Auto Mode PS 00 Primary Feed Turn on the power switch of HAKKO FU 500 The start up screen will be displayed and then move to Auto Mode Standby screen If the HAKKO FU 500 receives a Start signal...

Page 13: ...ceived Auto Mode PS 00 Primary Feed Turn on the power switch of HAKKO FU 500 The start up screen will be displayed and then move to Auto Mode Standby screen If the HAKKO FU 500 receives a Start signal...

Page 14: ...than Exit Tens place Units place Confirm Tens place Units place One decimal place Confirm For feed amount or feed speed tens place units place one decimal place For heating time units place one decim...

Page 15: ...Feed Speed 3 Back Feed 3 Back Speed 3 Heat Time 3 Preset Status Sig Primary Feed Length Primary Feed Speed Primary Back Feed Length Primary Back Speed Primary Heat Time Secondary Feed Length Secondar...

Page 16: ...ternal Secondary heating Internal Tertiary feed Internal Tertiary back feed Internal Tertiary heating Internal Status signal Form1 Out Status signal Form2 Out 15 Selecting Parameter Set When you selec...

Page 17: ...Tertiary heating Internal Status signal Form1 Out Status signal Form2 Out Run 16 4 Iron Connect Connection status to the HAKKO FU 601 Connection or Disconnection When Not Connect is selected preset s...

Page 18: ...d guide nozzle Loosening the adjustment screw will allow you to move the entire solder feed guide set as shown in the figure below Move the solder feed guide set to the tip Loosening the adjustment sc...

Page 19: ...screws described in this manual The attachment of the solder feed pulley unit for 0 3mm BX1000 is different Refer to the How to set solder in the BX1000 Please be careful not to tighten the screw too...

Page 20: ...KO FU 601 ready input is Not Ready during Auto Mode or Manual Program Mode This error will not occur in Adjustment Mode or Continuous Feed Mode If the HAKKO FU 601 ready input is Not Ready before Auto...

Page 21: ...immediately stop the feed and show this error message on the LCD along with buzzer sound When a hardware error is detected the HAKKO FU 500 will immediately stop the feed and show this error message o...

Page 22: ...nings and cautions are placed at critical points in this manual to direct the operator s attention to significant items They are defined as follows WARNING Failure to comply with a WARNING may result...

Page 23: ...in the table below Before changing the solder diameter see How to change the solder diameter on page 17 Solder diameter mm 0 3 0 5 0 6 0 65 0 8 1 0 1 2 1 6 Up to 1kg bobbin of solder can be used Feede...

Page 24: ...saka 556 0024 JAPAN TEL 81 6 6561 3225 FAX 81 6 6561 8466 http www hakko com E mail sales hakko com 23 Part No BX1000 BX1001 BX1002 BX1003 BX1004 BX1005 BX1006 Part No BX1007 BX1008 BX1009 Part No BX1...

Reviews: