![background image](http://html1.mh-extra.com/html/hakko-electronics/ft-800/ft-800_instruction-manual_579877001.webp)
THE
RM
AL W
IRE
ST
RIP
PER
FT-800 station
Hexagon wrench (1.5mm)
Handpiece
Blade (AWG18 to 28)
Lead adjustors A/B
Heat resistant pad
For left handed use
(In this case, the wire stripping length is 5 mm.)
Wire stripping length
For right handed use
Frange
Handle
THE
RMA
L W
IRE
ST
RIP
PER
THE
RMA
L W
IRE
ST
RIP
PER
THE
RM
AL W
IRE
ST
RIP
PER
Heater lamp
Flashing
Heater lamp
ON
Power save lamp
ON
Power save lamp
OFF
THE
RMA
L W
IRE
ST
RIP
PER
Knob mount
Handpiece
holder
Receptacle
Connection
cord
THE
RMA
L W
IRE
ST
RIP
PER
1 mm
5 mm
FT-800 station
1
Handpiece
1
Blade (AWG18 to 28) (2 pcs/set)
1
Lead adjustor A
1
®
2. SPECIFICATIONS
3. WARNINGS, CAUTIONS AND NOTES
5. OPERATION
4. ASSEMBLY
Model Name
Power Consumption
FT-800
120V AC / 68W
Output Voltage
Temperature Range
Dimensions
Weight (w/o cord)
FT-800 station
24V AC
Approx. 200 to 800
°
C (392 to 1472
°
F)
120(W)
×
93(H)
×
170(D) mm
(4.7
×
3.7
×
6.7 in.)
1.3kg (2.9lbs)
Warnings, cautions and notes are placed at critical points in this manual to direct the operator’s
attention to significant items. They are defined as follows:
WARNING:
Failure to comply with a WARNING may result in serious injury or death.
CAUTION :
Failure to comply with a CAUTION may result in injury to the operator, or damage to the
items involved.
NOTE :
A NOTE indicates a procedure or point that is important to the process being described.
Observe the following precautions to ensure safety.
CAUTION
WARNING
After the power is turned on, the blade temperature reaches approx. 200
°
C to 800
°
C (392
°
F to 1472
°
F).
Improper handling may cause burns or fire. Be sure to observe the following precautions:
Do not touch any metal area in the vicinity of blades.
Never use FT-800 near paper or other flammable materials.
Inform others in the area that the product is hot and should not be touched.
Turn the power off when not in use.
Before changing parts or storing the unit, be sure to turn the power off and allow the unit to cool to room
temperature.
Observe the following precautions to prevent accidents or damage to the unit.
Do not use the HAKKO FT-800 for applications other than wire stripping.
To remove stripped insulation waste, do not apply excessive force to the unit such as striking the blade
against the workbench.
Do not modify the HAKKO FT-800.
Do not allow the HAKKO FT-800 to become wet, and do not use it with wet hands.
Since smoke is produced when using the wire stripper, be sure to ventilate the work area fully.
Do not take any actions that might be dangerous.
l
Station
Power Consumption
Cord
Total Length (w/o cord)
24V AC / 64W
1.3m (4.27 ft.)
140mm (5.5 in.)
l
Handpiece
l
Connection cord
Pass the connection cord through the hole of the
heat resistant pad.
l
Blade attachment
1. Install the blades into the handpiece in the
correct direction as shown in the figures.
2. When attaching the blades, press them firmly
until the flange is locked into the handpiece.
NOTE:
Unless both blades are inserted fully, the blades
will not heat. Verify the flange of the blade comes
in contact with the handpiece.
CAUTION
Be sure to use the accessory heat
resistant pad when inserting or
removing the blade. Use the heat
resistant pad even when the blade is
not hot.
l
Lead adjustor attachment
The lead adjustor is used to set the wire
stripping length. See attachment directions for
proper installation.
NOTE:
The lead adjustor can set the wire strip length
from 1 - 19 mm or 20 - 38 mm.
The lead adjustor is marked with a 1 mm interval
scal. (Refer to the figure at right)
l
Turn on the power switch.
The
FT-800 station has a power save lamp and
the FT-8001 has a heater lamp.
After turning on the power, the heater lamp on
the FT-8001 will flash. The power save lamp on
the FT-800 station is lit when the FT-8001 is
placed in the handpiece holder.
When using the FT-8001, take the FT-8001 out
of the handpiece holder. When the temperature
stabilizes, the heater lamp will change from
flashing to being continuously lit.
l
Power save mode
When the FT-8001 is placed in the handpiece
holder, the power save mode is on. When in the
power save mode, the blade temperature is
reduced by approx.50% (under 300
°
C;572
°
F
).
Status of lamps during the power save mode
l
Temperature setting
1. Set the temperature adjustment knob to the
desired level.
NOTE:
Aging of the blade heater may deteriotate the
blade performace. If such a deterioration results
in a difficulty in melting the wire insulation, use
the temperature adjustment knob to raise the
temperature setting of the blade.
CAUTION
Since the temperature of the blade is very hot,
place the FT-8001 in the handpiece holder when
not using it.
Instruction Manual
1. PACKING LIST AND PART NAMES
Please make sure that all items listed
below are included in the package.
Lead adjustor B
1
Hexagon wrench (1.5mm)
1
Heat resistant pad
1
Instruction manual
1
THERMAL WIRE STRIPPER
Thank you for purchasing the HAKKO FT-800 thermal wire stripper.
Please read this manual before operating the HAKKO FT-800.
Keep this manual readily accessible for reference.
FT-800
FT-8001
Power save lamp
Heater lamp
ON
Flashing
Material
PVC, Nylon, Polyethylene
sheathed wires
Teflon, Silicon sheathed wires
Min. level
1
6
Temperature
Approx. 200
°
C
(392
°
F)
Approx. 600
°
C
(1112
°
F)
NOTE:
The blade temperature is determined for each
level as a reference, not as a guaranteed
temperature. The actual blade temperature will
decrease gradually with the aging of the blades.
2005.6
MA01435JZ050614
Power save mode
Operation mode
l
Connection
1. Connect the plug of the connection cord to the
receptacle.
2. Place the FT-8001 in the handpiece holder.
3. Insert the power plug into the plug outlet.
CAUTION
Turn off the power before inserting or removing
the plug of the connection cord from the recepta-
cle. The P.W.B. may be damaged if the power is
left on when inserting or removing the plug.
2. Locking the temperature adjustment knob. The
temperature adjustment knob is equipped with a
lock function. (Refer to the figure at right.)
After setting the temperature, tighten the
hexagon nut (clockwise) in the knob mount with
the hexagon wrench
CAUTION
Do not tighten the hexagon nut excessively.
CAUTION
Do not attempt to turn the temperature
adjustment knob with the knob locked.
NOTE:
The FT-8001 can be placed in the handpiece
holder with the heater lamp facing upward or
downward.
Handpiece holder
Button
Handle
Plug
Copyright © 2005 HAKKO Corporation. All Rights Reserved.
OVERSEAS AFFILIATES
U.S.A.: AMERICAN HAKKO PRODUCTS, INC.
TEL: (661) 294-0090 FAX: (661) 294-0096
Toll Free (800)88-HAKKO
4 2 5 5 6
http://www.hakkousa.com
HONG KONG: HAKKO DEVELOPMENT CO., LTD.
TEL: 2811-5588 FAX: 2590-0217
http://www.hakko.com.hk
E-mail:[email protected]
HEAD OFFICE
TEL:+81-6-6561-3225 FAX:+81-6-6561-8466
http://www.hakko.com E-mail:[email protected]
SINGAPORE: HAKKO PRODUCTS PTE., LTD.
TEL: 6748-2277 FAX: 6744-0033
http://www.hakko.com.sg
E-mail:[email protected]
Please access to the following address for the other Sales affiliates.
http://www.hakko.com/address