4
4. INITIAL SETUP
The front panel of HAKKO FR-810B includes five operation buttons.
- Used to start or stop the station.
•Pressing this button when the forced cool down bypass is
enabled will turn the airflow off and stop the cooling process.
- Used for changing values.
•Pressing this button when using Preset Mode will cause the
preset selection screen to appear.
- Used for changing values.
•Hold this button for at least two seconds to enter the Offset
Mode.
- Used for finalizing entered values and checking settings.
•Hold this button for at least two seconds to display the
temp/timer screen.
- Used to set air flow.
•
When setting the airflow, you may press or to
finalize your airflow setting value.
A. Station assembly
●
Attach the handpiece holder.
1. Turn and loosen the knob that locks the handpiece holder.
2. Slide the handpiece holder along the groove on the station in the direction of
the arrow. Turn the knob to lock the handpiece holder in place.
* The handpiece holder can be attached to either side of
the station by removing the handpiece holder attachment
plate and attaching it to the opposite side of the handpiece
holder.
●
Controls and displays
B. Handpiece
NOTE:
The handpiece can be used with the provided vacuum
pipe control knob (L).
CAUTION
The nozzle and pad will be heated at high temperature. Cool them before replacement.
●
Using vacuum function operative nozzle
1. Attach the nozzle.
a. Extend the vacuum pipe using the vacuum pipe control knob.
b. Pass the vacuum pipe through the nozzle hole and attach the nozzle.
CAUTION
●
Vacuum pipe
Do not use excessive force. When not using a nozzle,
retract the vacuum pipe to the shortest length.