This error occurs when there is the possibility of a sensor failure (or a
failure in the sensor circuit). The flashes and the power is shut
down.
This error occurs when the temperature of the hot air is falling even
though the heater is on. The flashes to indicate the possibility of
a heater failure.
This error occurs when there is the possibility of a fan failure. The
flashes and the power is shut down.
19
9. ERROR MESSAGE
● Sensor Error
● Heater Error
● Fan Error
10. TROUBLE SHOOTING GUIDE
When the error detection software in the HAKKO FR-810B detects an error, a message is displayed to
alert the operator. See “Troubleshooting” for procedures to correct the error.
● The unit does not operate when the
power switch is turned on.
●
is displayed
●
is displayed
●
is displayed
WARNING
Before checking the inside of the HAKKO FR-810B or replacing parts, be sure to disconnect the power
plug. Failure to do so may result in electric shock.
Is the fuse blown?
Investigate why the fuse blew and then replace the fuse. If
the cause can not be determined, replace the fuse. If the fuse
blows again, send the unit in for repair.
Is the sensor broken?
Measure the resistance value of the sensor. When the resistance
value is ∞, replace the heater.
Is the heater broken?
Measure the resistance value of the heater. The corr
ect values are approximately: 14Ω (
±10%
100-110V), 17Ω (
±10%
120V), 41Ω (
±10%
220-240V). When the resistance value is not
within the normal range, replace the heater.
The fan may be broken. Replace the fan with a new one.