background image

7

"MAX HOLD"

disappears 

indicating the 

function is 

cancelled.

MAX HOLD

MAX HOLD

MAX HOLD

Press the

button for

1 second or more

Max. temperature is updated.

Press the

less than 1 second

button for

Press the

less than 1 second

button for

MAX HOLD

 

MAX HOLD function (Temperature

measurement only)

Quickly pressing the 

 button will cause "

MAX 

HOLD

" to be displayed at the bottom of the 

screen. As long as "

MAX HOLD

" is shown, the 

maximum temperature will stay displayed. 

Operation method

 Pressed quickly (less than one second)

"

MAX HOLD

" is displayed at the bottom

of the screen.

•  

Pressed quickly (less than one second)
(

"

MAX HOLD

"

 is displayed )

By pressing the button quickly, the

displayed value will be reset and the

maximum temperature after pressing the

button will be displayed.

•  

Pressed for a long time (1 second or
longer)

The MAX HOLD function will be released

and the product will return to normal

display.

 CAUTION

 Turning off the power always cancels the

MAX HOLD function.

 The MAX HOLD function can only be used 

during the temperature measurement.

HAKKO FG-101B can use the following functions.

4-4  Measurement of resistance difference between tip and ground wire

4-5  Explanation about various functions

1)

Plug the power plug of the soldering iron to be measured into the power receptacle the

HAKKO FG-101B main body.

2)

Wait until the tip reaches the set temperature. If the soldering iron temperature is variable,

set temperature to maximum.

3)

Press the SELECT button and change the mode to "

OHM

".

4)

Press the 

 button. {Refer to "

 AUTO ZERO function

" (page 8) in "

4-5 Explanation

about various functions

".}

5)

Perform the measurement in the same procedure as "

4-3 Measurement of leak voltage

".

Summary of Contents for FG101B-03

Page 1: ...emperature leak voltage and ground resistance Please read the manual carefully before operating the HAKKO FG 101B Please keep this manual readily accessible for reference Instruction Manual SOLDERING...

Page 2: ...TIONS AND NOTES 3 4 OPERATION 4 4 1 Initial setup 4 4 2 Measurement of tip temperature 5 4 3 Measurement of leak voltage 6 4 4 Measurement of resistance difference between tip and ground wire 7 4 5 Ex...

Page 3: ...isplay contents 1 This alarm indicates sensor burnout If this alarm occurs replace the sensor 2 When the and buttons are held pressed simultaneously for a long time 1 sec or longer the count is reset...

Page 4: ...nctions Temperature measurement count function 000 to 999 times Power consumption 100V 3 2W 100 110V 3 6W 120V 3 2W 220 240V 3 6W Outline dimensions 211 W 53 H 126 D mm Weight 0 95 kg Usable temperatu...

Page 5: ...rning use of the appliance in safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Be...

Page 6: ...will move toward the terminal 2 Attach the sensor with the slide pin moved toward the terminal 3 Attach the sensor having a red mark to the red colored terminal and the sensor having a blue mark to th...

Page 7: ...When flux is stuck on the terminal wipe it off with alcohol Do not use thinner or benzin for wiping Read the values when the display temperature is stable CAUTION Do not measure the temperature by ap...

Page 8: ...ed into the power receptacle the HAKKO FG 101B main body 2 Wait until the tip reaches the set temperature If the soldering iron temperature is variable set temperature to maximum 3 Press the SELECT bu...

Page 9: ...the button will be displayed Pressed for a long time 1 second or longer The MAX HOLD function will be released and the product will return to normal display CAUTION Turning off the power always cance...

Page 10: ...Each time the button is pressed the AUTO HOLD function toggles between ON and OFF The AUTO HOLD function does not assume the measurement by temperature probes such as the hot air Data send function in...

Page 11: ...performed smoothly using the functions of connected stations Ground terminal GND When using a type of soldering iron that is grounded with an alligator clip connect the clip to the GND terminal Maint...

Page 12: ...r cord 3 core BS plug India B2424 Power cord 3 core European plug 220V KC 230V CE B2425 Power cord 3 core BS plug 230V CE U K B2426 Power cord 3 core Australian plug B2436 Power cord 3 core Chinese pl...