6

6.  Operation

 CAUTION

 

During measurement with this product, a trace amount of current flows to the human body. People 
with a weak heart or those using a cardiac pacemaker should not use this product.

 

Users that are pregnant, please refer to the technical document "FG-465 Information Regarding 
Safety to the Human Body" which can be found on our homepage (https://doc.hakko.com) and 
consult with the proper medical specialist.

Measurement

(1)  Turn the power switch ON. The preset pass range indicator LED lights.
(2)  Put on the anti-static footwear, and step onto the test plate making sure that the correct 

foot is on the correct side.

(3)  Gently press the pad with three fingers as shown in the figure below.

(4)  The left foot is measured first followed by the right foot.

Note

Measurement of the left foot is started from the center of the preset pass range or from 
just above the center (when range LED indicates an even number).

Example:  When pass range is 0.1 MΩ ≤ R ≤ 1000 MΩ, measurement is started from the 

10 MΩ ≤ R ≤ 100 MΩ range.

Note

Measurement of the right foot starts from the range finalized by measurement of the left 
foot. If there is no problem with the footwear, the range movement becomes minimum. 
This results in a shorter measurement time.

(5)  The pass/fail result is displayed.

Note

If you move your hand away from the pad before measurement is completed, the 
buzzer sounds three times.  
Pass/Fail results will not be shown. Repeat the measurement.

(6)  After you have confirmed the pass/fail result, move your hand away from the pad, and step 

off the test plate.

Note

If you move your feet on the test plate or contact between your fingers and the pad is 
poor, this may result in false measurement.  
During measurement stay still on the test plate and firmly place three fingers on the pad.

*  This product can be used without being grounded. However, we recommend grounding the GND terminal (for 

details on terminal position, see "4. Names of Parts") on the left side of the body.

When PASS LED lights

This indicates that the anti-static footwear is in a normal state.
The level indicator LED lights which indicates which range the resistance value of the footwear is in. 
This also allows you to check the properties of the anti-static footwear.

Summary of Contents for FG-465

Page 1: ...ontents HAKKO FG 465 1 Installation base 1 AC adapter 1 Test plate 1 Knobs 2 USB cable 1 Pan head screws M5 x 10 2 Wood screws DN 4 5 x 16 2 Instruction Manual this document 1 HAKKO FG 465 Wood screws...

Page 2: ...85 D mm 4 7 1 2 7 3 in Weight 0 55 kg 1 2 lb including installation base Test plate Cord length 1 6 m 5 2 ft Dimensions w o cord 300 W 30 H 300 D mm 11 8 1 2 11 8 in Weight w o cord 1 9 kg 4 2 lb AC a...

Page 3: ...specialist Current flowing through human body 2 to 3 A approx reference value measurement on the antistatic shoes 20 M Current flowing through human body 50 to 100 A measurement on bare feet Wearing t...

Page 4: ...e UP Connection cord UP mark at toes Left foot Right foot See External output P 8 UP Power switch Connection cord Test plate left foot Test plate right foot Pad Pass range indicator Connection port fo...

Page 5: ...Insert the connection cord from the test plate and AC adapter plug into the jacks on the left side of the body 4 Insert the AC adapter into the power outlet CAUTION When mounting this product on a wal...

Page 6: ...ge Note Measurement of the right foot starts from the range finalized by measurement of the left foot If there is no problem with the footwear the range movement becomes minimum This results in a shor...

Page 7: ...M DIP switch CAUTION Before changing the DIP switch settings be sure to turn the power OFF DIP switch setting table Setting DIP switch No 8 7 6 5 4 3 2 1 Electrical Conductivity R 0 1 M ON ON Lower l...

Page 8: ...Terminal block for external output conditions of use Model XW4C 03E1 H1 made by OMRON Stripped length of lead 10 mm Applicable lead Single wire 0 2 mm2 4 0 mm2 Strand wire 0 2 mm2 2 5 mm2 Rod terminal...

Page 9: ...he FG 465 ON When these are connected correctly the buzzer sounds twice When the power is turned ON on just the FG 465 the buzzer sounds once During measurement the LED on the FG 470 changes state Thi...

Page 10: ...tch setting table The buzzer just sounds 3 times and the pass fail result is not output Did you move your hand away from the pad quickly Do no move your hand away from the pad until PASS or FAIL is fi...

Page 11: ...adapter CH plug B5119 AC adapter BS plug B5220 AC adapter European plug CE B3528 AC adapter 2 Core Flat pin plug 4 B1991 Knobs qty 2 5 B5262 USB cable 1 m Mounting example a c b Options Dwg No Part No...

Page 12: ...GAPORE HAKKO PRODUCTS PTE LTD TEL 6748 2277 FAX 6744 0033 https www hakko com sg E mail sales hakko com sg HONG KONG HAKKO DEVELOPMENT CO LTD TEL 2811 5588 FAX 2590 0217 https www hakko com cn E mail...

Reviews: