![background image](http://html1.mh-extra.com/html/hakko-electronics/807/807_instruction-manual_3300622013.webp)
REPLACEMENT PARTS
Filter holder
Spring filter
Ceramic paper filter(L)
Back holder
Filter pipe
Spring Ffilter
Filter holder
Front holder
1
2
3
4
Pins
Fastener
24V
60W
24V
60W
Fig. 3
Fig. 2
Fig. 1
Nut
Nozzle
9
Front holder
2
3
5
1
4
6
7
Back holder knob
Fig. 4
9
CAUTION
Securely insert the spring filter to
the end of the filter holder.
Element cover
●
Replacing the filters.
1. Turn the back holder knob counterclock-
wise and pull out the filter pipe.
2. If there is solder in two-thirds of the spring
filter, replace the filter.
3. If the ceramic paper filter is stiff with flux
and solder, replace the filter.
4. Insert the spring filter into the filter pipe.
5. Insert the ceramic paper filter and put the
back holder into the filter pipe.
6. Insert the filter pipe into the main body
and secure it by turning the back holder
knob clockwise.
●
Replacing the
heating element
Check the resistance value
The resistance values of a working heating
element are
9.2
Ω
between pins 1 and 3 (heating element),
54
Ω
between pins 2 and 4 (sensor) at 73
°
F (23
°
C)
If the measured values are outside this
range, replace the heating element.
(No. A1174 24V-60W heating element for
Hakko 807)
Replacing the heating element
1. Unplug the cord.
2. Remove the nut, element cover, and
nozzle.
3. Turn the back holder knob counterclock-
wise and pull out the filter pipe.
4. Remove the housing fastener.
5. Remove the screws securing the housing
9
and the screws
3
4
securing the
flange to the housing.
6. Remove the front holder.
7. Remove the screw
5
6
7
securing the
heating element to the flange, and the
screw
1
2
.
12