7. PARTS LIST
l
Absorption pipe set
8
Item No. Part No.
Part Name
Description
➂
B1291 Silicone hose
1 m (3.28 ft.)
➃
B1290 Hose coupling band
5 pcs.
* Absorption pipe set R (No. 1540) has a different silicone hose from other ones
(No. C1029 – C1086).
l
No. C1029 [Absorption Pipe Set A/DASH, 900M/L]
Item No. Part No.
Part Name
Description
➀
B1280 Absorption pipe A
6.5 × 100
➁
B1284 Metal fitting for absorption pipe A
l
No. C1030 [Absorption Pipe Set B/MACH-I (920,921,922)]
Item No. Part No.
Part Name
Description
➀
B1280 Absorption pipe A
6.5 × 100
➁
B1285 Metal fitting for absorption pipe B
l
No. C1031 [Absorption Pipe Set C/MACH-I (918)]
Item No. Part No.
Part Name
Description
➀
B1280 Absorption pipe A
6.5 × 100
➁
B1286 Metal fitting for absorption pipe C
l
No. C1033 [Absorption Pipe Set E/MG (30 W – 100 W)]
Item No. Part No.
Part Name
Description
➀
B1282 Absorption pipe C
6.5 bent
➁
B1287 Metal fitting for absorption pipe D
l
No. C1034 [Absorption Pipe Set F/455]
Item No. Part No.
Part Name
Description
➀
B1281 Absorption pipe B
6.5 × 130
➁
B1288 Metal fitting for absorption pipe E
l
No. C1035 [Absorption Pipe Set G/456]
Item No. Part No.
Part Name
Description
➀
B1283 Absorption pipe D
6.5 × 140
➁
B1289 Metal fitting for absorption pipe F
l
No. C1086 [Absorption Pipe Set H/902, 904]
Item No. Part No.
Part Name
Description
➀
B1596 Absorption pipe E
6.5 × 80
➁
B1284 Metal fitting for absorption pipe A
B1597 Cup nut
B1999 Wave washer
l
No. C1540 [Absorption Pipe Set R]
Item No. Part No.
Part Name
Description
➀
B1953 Absorption pipe
6.4 bent
➂
B2184 Silicone hose
1.5 m (4.92 ft.)
➄
B3246 Metal fitting for absorption pipe R
* The smoke absorption pipe cannot be attached with No. C1540, if the handle
diameter of soldering irons is more than 16 mm.
l
Duct Set
Item No. Part No.
Part Name
Description
➀
B1276 Filter cap
➁
A1074 Pre-filter
5 pcs.
➂
B1278 Filter case
➃
B1279 Duct
1.5 m (4.92 ft.)
➄
B1292 Nylon strap
2 pcs.
➀
➁
➂
➃
➄
➄
➁
➂
➃
*Illustration for absorption pipe set A (No. C1029)
➀
4. PART NAMES, ASSEMBLY PROCEDURE
1. Connect the exhaust duct.
l
Connect the exhaust duct to the outlet of
the station.
(Attach the exhaust duct to the root of the
outlet.)
2. Assemble the duct set.
l
Place the pre-filter in the filter case and
attach the filter cap to the filter case.
l
Connect the duct to the filter case and
attach the end cover to the other end.
(Put the end cover on the filter case which is
placed at the end.)
3
3. Connect the absorption pipe set.
l
Attach the soldering iron to the absorption
pipe set.
(Refer to “ASSEMBLING THE
ABSORPTION PIPE SET” on page 5).
l
Bind the silicone hose and soldering
iron power cord together with the hose
coupling band.
l
Attach the silicone hose to the tip of the
filter cap.
4. Connect the duct.
l
Connect the duct to the inlet socket.
l
Place the main filter in the pipe for main
filter on the station and connect to the inlet
socket.
Grounding Terminal
Fuse Holder
( Internal fuse:
125 V, 5 A)
Pipe for Main Filter
Insert main filter and
connect inlet socket.
Suppressor
Used to suppress the
exhaust sounds during
use.
Exhaust Duct
5 m (16.4 ft.)
Inlet Socket
Power Switch