The  HAKKO  192  converts  the  measurements  to  DC  voltage  values  and 

outputs  these  values  from  the  monitor  output  terminal.  See  the 

"Specifications" table on the previous page for voltage values.

Be careful when using monitor output; as measurements are converted to 

DC voltage values, monitor output may not match the values shown on the 

display.  There  will  also  be  some  error  on  the  part  of  the  instrument  to 

which these values are output.

 Ground Terminal (GND)

The  ground  terminal  (GND)  is  connected  to  the  ground  line  for  the 

soldering  iron  outlet  on  the  HAKKO  192.  It  is  used  when  deriving  the 

values  for  V1  and  R1  during  measurement  of  the  difference  in  potential 

and the resistance, respectively, between the tip and ground.

When using a type of soldering iron that is grounded with an alligator clip, 

connect the clip to the GND terminal.

 Maintenance and Calibration

 Replacement Parts

To replace the conduction plate, remove the set screws.

The life of the temperature sensor will vary depending on the temperature 

at which measurements are made and the type of solder and flux being 

used. In general, temperature sensors can be used for 50 measurements. 

Replace the sensor as soon as the measuring point wears out.

HAKKO  can  calibrate  the  instrument  for  a  nominal  fee.  Please  contact 

your dealer for further information.

Part No.
191-212
B1752
B1754
B1950
B2705

Part Name
Temperature sensors (10 pcs.)
Conduction plate
Ground clip
Conduction wire
Midzet fuse (5A)

■ 

Procedure

 

Preparations

1. Attach the ring plate to the slide pole.

2. Move the slide button in the direction indicated by the arrow in the figure 

below, then attach the sensor as shown in the drawing (place the red end 

on the side with the red dot, and blue end on the other side of the 

terminal).

3. Insert the power plug into the outlet and turn the power switch on.

Be sure to insert the power plug into a grounded (3-hole) outlet.

Power will be supplied to the outlet on the HAKKO 192 only when the 

unit is plugged in and the power switch is turned on.

9. When the display has stabilized, read the value. (V2)

If the soldering iron power plug uses an alligator clip rather than a 3-

prong grounded plug, connect it to the GND terminal with the ground clip 

and then perform measurements.

10.Subtract V1 from V2 to derive the difference in potential between 

the tip and the and the ground.

V = V2 - V1

Measuring the tip temperature

Measuring the difference in potential between tip 

     and ground

1. Press the           

    

select switch.

2. Clean the tip and coat it with fresh solder

3. Quickly place the tip on the measuring point on the temperature sensor.

As shown in the figure below, place the tip properly on the measuring 

point in accordance with the type of tip being used, as if you were 

soldering that point.

4. The value shown in the display will increase; wait two (2) to three (3) 

seconds for it to stabilize.

Measuring the resistance between tip and ground

1. Press the OHM select switch. Using the same procedure as when 

measuring the difference in potential, measure the values for R1 and R2 

(which correspond to V1 and V2 in that procedure).

2. Subtract R1 from R2 to derive the resistance between the tip and 

ground.  R = R2 - R1

Over range display

1. Plug in the soldering iron by inserting the plug on the power cord into the 

receptacle on the HAKKO 192.

2. Wait until the tip reaches the set temperature. If the soldering iron is a 

variable tip temperature model, set temperature to the maximum.

3. Press the mV select switch.

4. Using the ground clip, connect the ground terminal (GND) on the HAKKO 

192 to the conduction plate.

5. Read the value on the display. (V1)

6. Disconnect the ground clip.

7. Clean the tip and coat it with fresh solder.

8. Place a tiny bead of solder in the center of the conduction plate and heat 

the bead until the solder has completely melted.

TEMP

The over range code is              . An over range occurs during temperature 

measurement when the temperature sensor is not attached, and during 

voltage and resistance measurement when the tip is not in contact with the 

conduction plate.

Note:

When using fine tips at low temperatures and the solder is hardly melted 

on the conduction plate, use the attached conduction wire. Measuring 

with conduction plate meets MIL standard; always use the conduction 

plate except for the above written cases.

1. Remove the two (2) screws which secure the conduction plate.

2. Remove the conduction plate.

3. Secure the conduction wire with the same screws in place of the 

conduction plate.

 Optional Parts