Instruction Manual

■ 

Packing List

HAKKO 192

1

Temperature sensors

10

Ring plate

1

Ground clip

1

Midzet fuse (5A)

1

Conduction wire

1

Instruction manual

1

■ 

Precautions

■ 

Specifications

Midzet fuse (5A)

Ground clip

Display

Conduction wire

Power cord

Power plug

Receptacle

Fuse holder

Power switch

Conduction plate

Select switches

Monitor 

output

Ground 

terminal

■ 

Part Names

Handle  the  temperature  sensor  carefully.  The  temperature  sensor  is 

extremely thin ø0.2 and may break if pressed with too much force.

The  measuring  point  on  the  temperature  sensor  has  been  specially 

processed, but repeated measurements will cause it to wear out. Replace 

it promptly to ensure the accuracy of measurements.

When there is flux on the terminal, wipe it away with a cloth that has been 

moistened with alcohol. Do not use paint thinner or benzene.

Before  measuring,  coat  the  soldering  iron  tip  with  fresh  solder.  This  is 

necessary to ensure proper contacting between the tip, the temperature 

sensor, and the conduction plate.

Instead of the over range code  –1 , a value will sometimes be displayed 

when  the  tip  is  not  touching  the  conduction  plate  during  voltage 

measurement. This is normal.

During voltage and resistance measurement, make sure that the power 

cord has been inserted into a grounded (3-hole) outlet.

When  voltage  and  resistance  measurements  are  greater  than  the 

prescribed values, check the tip and make sure the fastening screws of 

soldering iron are not loose, then measure again.

1.

2.

3.

4.

5.

6.

7.

Resolution
Measurement range
Precision

Sensor
Resolution
Measurement range
Accuracy
Conforms to MIL-STD-2000
Resolution
Measurement range
Accuracy
Liquid crystal display (LCD)
Over range
Temperature
Voltage
Resistance
Burn out

1W
200 (W)    50 (H)    120 (D) mm
7.9 (W)    2.0 (H)    4.7 (D) in.
Approx.1.1 kg/2.4 lbs.
0  to  40

°

C  (32  to  104

°

F),  20  to  90%  RH,  no  dew 

1

°

C/1

°

F

0 ~ 600

°

C/0  ~ 1200

°

F

±

3

°

C (in 300 ~ 500

°

C range)

±

6

°

F (in 572 ~ 932

°

F range)

K (CA) thermocouple
0.1 mV
0 ~ 90 mV (AC)

±

 (5% of r 1 digit)

0.1
0 ~ 90

±

 (5% of r 1 digit)

3  /

2

 digits

1 mV/

°

C, 

°

F

10 mV/mV
10 mV/
-7 V (max.)

Temperature

Voltage

Resistance

Display

Monitor output

Power consumption

Dimensions

Weight (w/o cord)

Operating environment

Thank you for purchasing the HAKKO 192 soldering tester.

Please read this manual before operating the HAKKO 192. 

Keep this manual readily accessible for reference.

The HAKKO 192 cannot be used with ungrounded soldering irons. 

Ground  the  soldering  iron  by  plugging  it  into  a  grounded  (3-hole) 

outlet.