Operating Instructions
electronic solenoid valve control type
IFC 30
operating instructions
Ifc30-ba_eng
Version: 02/2015
Date: 26.02.2015
Page: 8
4.1 Safety notes for the installation
IMPORTANT NOTICE!
Install according to the manufacturer´s instructions and the respective national regulations
and provisions as well as the relevant installation regulations.
Connect and carry the ground wire.
4.2 Safety notes for the installation of the add-on housing
IMPORTANT NOTICE!
The unit must be installed such that the degree of protection IP 65 to EN 60529 is
guaranteed (state of delivery).
Therefore it is important
to fix all screws of the lid,
to mount the cable entries competently,
to close unnecessary cable entries with stoppers,
to use in the ex-area only cable glands and stoppers approved for this area.
The requirements of the EN 60079-14 must be met.
In addition, only the connection of permanently installed cable and wire is allowed. A
corresponding strain relief must be ensured.