mandoteX – Disassembly
7.2.2 Disassembly of the clamping device with clamping device adapter
6. x
For the disassembly of the mandrel with clamping de-
vice adapter from the machine adapter the following
steps are to be done:
1. Move the drawtube of the machine into front end
position.
Fig. 26
2. Loosen and remove the longer cylindrical screws
[E2].
3. Unlock the clamping device by turning it clockwise
in the bayonet clock.
4. Remove the mandrel with the assembled clamping
device adapter from the machine adapter [see fig.].
The clamping device is disassembled.
46
Order h49 7144.907-333