5.11
Installation of the hinged rest platform
Installation example
Fig. 24: Installation of the hinged rest platform
A hinged rest platform must be installed at a
maximum height of 10 m above the access
lever for system heights ≥
10 m in accordance
with DIN 18799-1.
Another hinged rest platform must be installed
on the access ladder every additional 10 m.
A maximum distance of ≤ 9
m between 2 rest-
ing folding platforms is permitted in wind turbine
generators in accordance with DIN 50308.
A maximum distance of ≤
12 m is permitted be-
tween 2 hinged rest platforms in accordance
with EN 14122-4.
Installation of the hinged rest platform – two-
section surface –on the ladder rung. (Aluminium
access ladder,
inside ladder dimension > 370 mm)
NOTE
Tighten the hexagonal nut [X] only so far that
the hinged rest platform can still pivot