Hailo BFD-50-136 Manual Download Page 5

5

•   Only persons who have been instructed in the 

use of vertical ladder and fall protection systems 
may use the H-50 fall protection system and the 
SPL-50-PRO fall arrester. The user of the fall ar-
rest system must be physically and mentally ca-
pable of movement using the respective equip-
ment. Safety in normal or emergency conditions 
must not be compromised.

•   The contractor or operator of a plant must put in 

place a plan which covers all possible emergen-
cies that might arise when using the fall arrest 
system and outlines the measures required for 
rescuing personnel.

•   The accident prevention regulations  

DGUV regulation 1 and  
DGUV rules 112-198/199 (Germany)  
must be respected. 
Testing must adhere to the respective national 
operating and testing regulations.

•   No changes or additions may be made to the 

H-50 fall protection system without the pri-
or written consent of Hailo. Repairs may only be 
carried out using original parts and in accor-
dance with Hailo‘s instructions.

•   The SPL-50-PRO fall arrester is designed for use 

in temperatures ranging from - 40°C to + 50°C.
The safe function of the fall arrester can be im-
paired e.g. by extreme climatic conditions, che-
micals, contamination or mechanical influences 
(sharp edges, oil, ice, etc.). Use in this case is 
prohibited.

•   No more than 5 persons may use the fall arrest 

system at the same time. The distance between 
individual users must be at least 6 m.

•   The H-50 fall arrest system is designed as a fall 

safety when using rung ladders and pole clim-
bers, both above ground and below ground.  
It is designed for a safe ascent and descent of 
service personnel to workstations at higher or lo-
wer levels.

•   The SPL-50-PRO fall arrester is approved exclu-

sively for securing persons with a total weight 
(body weight of the user including clothing and 
equipment) of 50 - 136 kg.  
The use of climbing aids is prohibited unless the 
safe usability of the combination in question has 
been explicitly demonstrated. 

•   Users of the H-50 fall arrest system, along with 

their fall safety personal protective equipment 
(PPEgA), connect to the fall arrester, which runs 
along the entire length of the ladder system.  
(see page 6). 

•   The fall protection system may only be used 

within the operating conditions described in this 
information booklet.  
Any other use (e.g. as workplace positioning or 
as an anchor point) is prohibited and can lead to 
failure of the safety system in the event of a fall.  
No liability is assumed for personal injury or pro-
perty damage resulting from violations of the 
provisions outlined in this booklet or from failure 
to comply with the safety instructions.

 

3.  Intended use 

 

4.  Safety instructions

Summary of Contents for BFD-50-136

Page 1: ...ion booklet about Using Care Inspection Guided type fall arrester including rigid anchor line H 50 System Hailo SPL 50 PRO Fall Arrester and Integrated BFD 50 136 Shock Absorber EU 2016 425 DIN EN 353...

Page 2: ...is necessary for the safety of the user that the retailer provides the user with the informa tion in this booklet in the respective national language The SPL 50 PRO fall arrester may only be used on t...

Page 3: ...gerous situations If these cannot be avoided there is a risk of injuries Notes on potentially dangerous situations If these cannot be avoided there is a risk of severe injuries or death CAUTION WARNIN...

Page 4: ...bsorber No No Expiry date Company Fax Postcode Town Name Telephone Street E mail Date of the first use Date Signature of manufacturer Company stamp Information on SPL 50 PRO fall arrester Date Signatu...

Page 5: ...rp edges oil ice etc Use in this case is prohibited No more than 5 persons may use the fall arrest system at the same time The distance between individual users must be at least 6 m The H 50 fall arre...

Page 6: ...bout the safe use of the device or if the device has been damaged as a result of a fall it must be immediately with drawn from use and returned to Hailo for inspec tion and repair In the event of a fa...

Page 7: ...7 B D C E F WARNING Risk of falling The user should basically avoid standing in a position on the fall arrest rail where they are directly above the fall arrester F Warning Risk of falling...

Page 8: ...nnes utilisant l acc s une distance d au minimum 6 m doit tre respect e 5 personnes au maximum peuvent utiliser en m me temps le syst me de protection d acc s en hauteur Le syst me H 50 doit tre utili...

Page 9: ...L 50 PRO fall arrester is designed such that it is not possible to thread the device incor rectly onto the fall arrest rail The fall arrester cannot be opened or closed in the wrong pulling direction...

Page 10: ...ur right hand 3 Attaching the fall arrester Attach the fall arrester to the profile of the fall arrest rail first from the left and then from the right 4 Locking the fall arrester Release the slide C...

Page 11: ...l arrester from sliding out of the fall arrest rail unintentionally WARNING Risk of falling Before the end stop is brought into the transit position the user must secure themselves with a lanyard to a...

Page 12: ...l within 30 mm without slipping If there is any doubt as to whether it can be used safely the fall arrester must be taken out of ser vice immediately Checking the wearing points at the brake lever In...

Page 13: ...op devices stop points that are situated above them Additional anchor points WARNING Risk of falling Both on entering and leaving the fall arrest system the user must be secured to an approved fasteni...

Page 14: ...r B Security advice C Test badge D Arrow marking THIS WAY UP E Type plate on BFD 50 136 shock absorber F Shock absorber address sticker G Hailo Professional Logo H Packaging label 7 Markings SPL 50 PR...

Page 15: ...by trained authorised personnel The testing of all components each individual subsystem and system must be documented In addition regular checks must be made depending on the respectively applicable...

Page 16: ...cal condition 7 Brake lever wear points Check thickness min 0 05 mm see page 12 8 Brake lever recuperating spring Impact and condition 9 Screw connections Technical condition and preload force 10 Cyli...

Page 17: ...YES OK not OK N0 YES Inspection 4 Date Month Year NO YES OK not OK N0 YES Inspection 5 Date Month Year NO YES OK not OK N0 YES Inspection 6 Date Month Year NO YES OK not OK N0 YES Inspection 7 Date M...

Page 18: ...0 PRO fall arrester Product description Manufacter Supplier SPL 50 PRO fall arrester 11 Documentation Inspection of the SPL 50 PRO Fall Arrester Copy this double page when additional information needs...

Page 19: ...ufacturer a Replace shock absorber and shackle b Fit shackle bolts with safety stickers Bearbeiter in Name und Unterschrift HAILO Werk Daimlerstra e 2 D 35708 Haiger 49 0 2773 82 0 49 0 2773 82 1561 i...

Page 20: ...1215919 Revision 2021 02 Technical changes reserved...