 Sensing element: NTC 

 Set-point range: (could set upper/lower limit) 

Inside sensor:5-35

 [41-95

]

 

Outside sensor:5-45

[41-113

Only outside sensor:0-90

[32-194

 Operating temperature: 0-45

 [32-113

 Operating    humidity: 5-95%RH ( non-condensing ) 

 Button: Silicone Rubber Keypad 

 Power supply: AC85-250V

50/60Hz 

 Power consumption: <3W 

 Wirings: Wiring 0.0016x0.0062sq. in.( 1×4 mm

wires) 

 Switch current rating: 16 A(Resistive) 

 Housing: PC

ABS Flame Retardant 

Dimensions:2.95x4.82x1.04”   

(75×122.5×26.5mm) (W×H×D) 

 Hole pitch: 3.29” (83.5 mm)(standard) 

 Protection class:IP30 

OPERATION 

 On/Off: Press “POWER” to turn on, press “POWER” again to turn off, and off the electric heating equipment at the same time. 

 Setting temperature: When power is on, press “Down” to reduce set-point, press “Up” to raise set-point. (0.5

℃ 

[1

] changed each press.) 

 Electric heating equipment’s control: When the room temperature is 1

 (when the offset is 2

) lower than the setting temperature, the thermostat will put through the power of the 

electric heating equipment, and the LCD will display “ ”; When the room temperature is 1

 (when the offset is 2

) higher than the setting temperature, the thermostat will close the power of 

the electric heating equipment, and “ ” will disappear. 

 If open the ”output delay” function, (refer to No.15 and No.16 of the parameter list): “ ” flashing means delaying, and the thermostat will output. When the delay time shows, the LCD 

shows “ ”, the thermostat output, and put through the power of the electric heating equipment. 

MANUAL MODE

TIMER ON/OFF FUNCTION MODE AND 4 PERIODS MODE CHOICES 

 Timer on: Press “Mode” for 3 seconds, LCD shows “XX”, press “Up” or “Down” to adjust the parameter. 

“01” stands for manual mode, that means after set the temperature, and no change, LCD shows “

”. 

“02” stands for timer on/off mode, LCD shows “

”. 

“03” stands for 4 periods mode, LCD shows corresponding time symbol. 

4 PERIODS’ CORRESPONDING SYMBOLS: 

Period 1 

Period 2 

Period 3 

Period 4 

Wake 

Leave 

Return 

Sleep 

 

 

 

 

TIMER AND TIMER ON/OFF FUNCTION SETTING 

Time adjust: press “Time”, till to display “hh:mm” and “hh” flashes

press “Up” or “Down” to adjust hour; press “Time”, “mm” flashes, press “Up” or “Down” to adjust minute; press “Time”, 

then week flashes, press    “Up” or “Down” to adjust week. 

 Timer on: Press “Time”, till to display “TIMER ON” and “hh” flashes

press “Up” or “Down” to adjust time on hour, press “Time”, “mm” flashes, press “Up” or “Down” to adjust the time 

on minute; Press “Time”, till “TIMER OFF” and “hh” flashes. Use the above method, setting the time on/off hour and minute, the time on/off will be valid until to be canceled. 

 Canceling timer on: Method 1: Setting the time on/off hour and minute as “00”; Method 2: As per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices”, 