background image

Opening the ProGuard800 control panel 

1.

Remove the ProGuard800 from its packing.

2.

Push the little pins at the bottom side of the central unit
gently with a screwdriver as shown on the picture and
move the screwdriver up.

3.

Remove the front of the central unit. You will see that
the front is connected to the backside with two
fasteners and the flat-cable of the keyboard.

Removing the back-up battery 

1.

Remove the back-up battery by pushing the bottom
side of the clip.

2.

Retain the battery and the clip well. They will be placed
in the panel later.

Disconnecting the internal siren 

Disconnect the internal sire. This is a bit more comfortable when 
you accidentally activate the siren during the installation. This is 
the upper white plug on the PCB mounted at the front panel of 
the ProGuard800. 

Connecting the telephone cord 

1.

Get the enclosed telephone cord from the box and
guide it through the hole on the back side of the central
unit. Connect the telephone cord to the left telephone
connector.

2.

Disconnect the cord of your main telephone
connection. Connect the other end of the enclosed
telephone cord to the now available main telephone
connection.

3.

Guide the disconnected cord of your main telephone connection through the hole
on the back of the central unit and connect this to the right connector.

Mounting the panel to the wall 

1.

The panel has four mounting holes.

2.

Position the panel on the wall and mark the holes with
the marker.

3.

Make sure you do not mark the holes in places where
there could be wiring in the wall.

4.

Drill the holes in the wall and place the enclosed
plugs.

5.

Place the two screws in the upper holes and let them
stick out 5 mm.

6.

Hang the panel at these upper screws.

7.

Now place the lower two screws, do not tighten them too much.

-3- 

 © 

HAIBRAIN 

Summary of Contents for ProGuard800 Series

Page 1: ...PROGUARD 800 20213 20100604 PROGUARD800TM ALL RIGHTS RESERVED HAIBRAIN ENGLISH PROGUARD800 SERIES QUICK INSTALLATION GUIDE...

Page 2: ...stone 6 mm Bit metal 4 mm x Marker x ProGuard800 set consisting of x Control panel x Motion sensor MS845 x Keyfob remote control KR814 x Door window sensor DS831 x Telephone cord with RJ11 Connectors...

Page 3: ...ard800 Connecting the telephone cord 1 Get the enclosed telephone cord from the box and guide it through the hole on the back side of the central unit Connect the telephone cord to the left telephone...

Page 4: ...anel When the control panel is in programming mode the first line always indicates the subject The second line always indicates the options With the keys you can step through the options With 9 you ca...

Page 5: ...icate that the ProGuard800 is still activated when you enter your house it is recommended to equip the entrance door with a Door Window sensor with an entrance delay When entering the ProGuard800 indi...

Page 6: ...ector between front and backside of the sensor Now move the screwdriver upward 2 Supply the Motion sensor with power by removing the red plate which separates the battery from the battery contacts 1 D...

Page 7: ...er contact or with the DS831 by moving the magnet from or to the sensor or with the MS845 by generating some movement The details of the transmitter now appear on the LCD display of the central unit B...

Page 8: ...ce the caps on the magnet and the sensor 5 The ProGuard800 has given a TAMPER ALARM for the DS831 when placing it Enter 1 2 3 4 on the Proguard800 when the caps have been replaced Placing the MS845 Wh...

Page 9: ...the display now shows 1 KF1 REGISTER TRANSMIT 2 Press once again one of the keys of the KR814 the display now shows 1 KF1 REGISTER SAVE Press 9 to confirm You will now hear a long beeping sound 7 Pres...

Page 10: ...d800 is now making a call If you pick up the telephone that is being called you will hear the following notification ProGuard800 alarm system system armed For the next message press 1 This notificatio...

Page 11: ...he display now shows 4 USER CODES USER 20 NON_CTRL 4 Press 9 the display now shows USER 20 NON_CTRL 1 EDIT CODE 5 Press 9 the display now shows 1 EDIT CODE 0000 6 The cursor is located at the first nu...

Page 12: ...ssing 9 followed by 1111 the display now shows MAIN MENU 1 STOP COMM 2 Press 94061 the display now shows 6 DISPLAY 1 ARM STATUS 3 Press 9 4 Press the display now shows 1 ARM STATUS DISPLAY ALWAYS 5 Pr...

Page 13: ...stered Zone Type Descriptor 1 to 2 ENTRY EXIT DS831 3 to 9 NORMAL DS831 11 to19 NORMAL MS845 21 to 22 FIRE SD833 23 to 24 FLOOD WD861 25 to 26 24 HOURS TS863 Keyfobs Two kinds of Keyfob transmitters c...

Page 14: ...N 9 3 TWO WAY AUDIO 9 ENABLED 5 EVENT OPTIONS 9 1 BURGLARY 9 1 RAPPORTAGE 9 ENABLED 9 d 2 RAPPORT HERST 9 ENABLED 9 d 3 TWO WAY AUDIO 9 ENABLED 9 d 2 FIRE 9 1 RAPPORTAGE 9 ENABLED 9 d 2 RAPPORT HERST...

Page 15: ...9 d 7 KF CTRL 2 9 DISABLED 9 d 8 TEL CTRL 2 9 DISABLED 9 d 9 RANDOMIZE 2 9 DISABLED 9 d 10 PULSE TIME 2 9 2 MIN 9 d 11 DESCRIPT 2 9 DIMMER MODULE 9 2 HOUSE CODE 9 A HOUSE CODE 3 HA CONTROL 9 ENABLED...

Page 16: ...ZI0488B 1 09...

Reviews: