AUTO:Auto operation mode 

The 2

nd

 column 

CHECK:Auto diagnostic,trouble shooting 
1: display the current failure code at temp. area, and 1 in fan speed area will be light.   
2: display the last failure code, at temp. area, and 2 in fan speed area will be light. 

Low fan speed 

:Medium fan speed 
:High fan speed 

AUTO:Auto fan running 
FIX: Fix fan speed,it will display only when fixed fan speed is requested to main indoor unit. 
CENTRAL:Central control mode 

The 3

rd

 column 

STANDBY:Waiting mode 
FILTER:Request of filter to be cleaned 
Preheat:Preheating mode 
DEFROST:Dfrosting mode 
LOUVER/MANUAL:Swing mode 

2. Operation 

2.1 Press ON/OFF button on wired controller. 
Wired controller will display the state of last time (timer, swing etc will not display). And air 
conditioner will run, LED of wired controller will be light. 
2.2 Select running mode 
Press “mode”, the mode will change as follow: 

  [AUTO]

[FAN]

[COOL]

[DRY]

[HEAT]

[AUTO] 

2.3 TEMP button 
Press TEMP +/- to set indoor temperature. 
The preliminary set temperature at any mode is 24 , but in FAN mode, no set temperature.

 

2.4 FAN button 
Press “FAN” button to select fan speed, fan mode will change as follow(in DRY mode, fan speed is 
AUTO): 

[AUTO]

[HIGH]

[MED]

[LOW]

[AUTO] 

In FAN mode, there is no AUTO FAN speed. 
If the main indoor unit needs to fix the fan speed, the fan speed can not be changed, and LCD will 
display FIX. 
2.5 SWING button 
Press SWING button, the flap will swing accordingly. 
2.6 ON/OFF button 
Press ON/OFF again, shut off the unit. LED of wired controller will be off. 

3. Installation 

3.1 Take off the top cover of wired controller, PCB is set at the top cover. Be careful not to damage 
PCB. 
 
*

.Dip switch setting 

item 

switch 

state 

function 

ON 

Set as slave wired controller 

Changeover 

between 

master/slave wired 

controller 

SW1 

OFF 

Set as master wired controller 

ON 

Display Fahrenheit 

Changeover 

between Celsius and 

Fahrenheit   

SW2 

OFF 

Display Celsius 

 
3.2 Requirement for wire between indoor and wired controller and communication wire 
Connect the terminals (A, B, C) at the bottom of wired controller with the terminals (A, B, C) on 
indoor PCB respectively. 

 