1. First, put communication wire through the hole in the back 

cover. 

Wired Controller Wiring Instruction

2. Fix back cover to the holder. After that, connect 

communication wire to CON1 port of wired controller. Finally 

put the front cover of wired controller to back cover to complete 

the installation.

Press this button to  open the back 

cover of the wired controller.

Controller Installation 

Summary of Contents for YR-E17A

Page 1: ... Installation Manual Please read this operation manual before using the wired controller Please keep this manual carefully and safely CONTENT Parts and Functions 1 Operation 6 Wired Controller Wiring Instruction 34 YR E17A Ver B ...

Page 2: ...1 Interface Display Parts and Functions ...

Page 3: ...e and other parameter value in other interface And the key is also used for function switching Time key Press this key to set clock time Timer and malfunction parameter queried Menu key Press this key to enter function circulation Also this key is used to confirm changes Key Parts and Functions Clock display parameter display Timer ON OFF ROOM SET temperature display Icon ...

Page 4: ...lay Only valid for part of models Up Down Swing Left Right Swing Only valid for part of models Set icon Auto mode Cooling mode Heating mode Fan mode Dry mode Turbo This icon will be displayed only when turbo function is set Quiet This icon will be displayed only when quiet function is set ...

Page 5: ...rgy Saving This icon will be displayed only when energy saving function is set Static Pressure This icon will be displayed only when setting static pressure function Filter Cleaning Child Lock This icon will be displayed only when child lock function is set Lock Central Motion Sensing only valid for part of models Master This icon will be displayed only when controller is set as master controller ...

Page 6: ... valid for part models Breeze Fan Speed Low Fan Speed Medium Fan Speed High Fan Speed Super Fan Speed Auto Fan Speed 2 fan speed only valid for part models Seven gear Sixth gear Fifth gear Fourth gear Third gear Second gear First gear Auto ...

Page 7: ... on off the wired controller Mode control In the state of on press the key MODE to change mode Adjusting temperature In the state of on press the key or to adjust temperature Adjusting fan speed In the state of on press the key FAN to adjust fan speed Basic function description ...

Page 8: ...cate with the indoor unit PCB normally after powering on the initialization will be finished in 4 minutes and then the communication malfunction can be checked from the malfunction inquiry function Backlight time 1 In the state of off when the backlight is lit up long press TIME and keys for 5 seconds to set backlight time the parameter value is displayed in the upper left corner Press or key to s...

Page 9: ...g press TIME key for 5 seconds to enter clock setting function At this time the minute of the time and icon are flashing in the upper left corner You can use or key to adjust the minute value and long press or key to speed up the adjustment Then press TIME key to switch to hour adjustment and use or key to adjust the hour value Finally you need to press MENU key to confirm the changes and return t...

Page 10: ...tion is as follows ON and the hour position are flashing ON and the minute position are flashing OFF and the hour position are flashing OFF and the minute position are flashing ON and the hour position are flashing ON and the minute position are flashing OFF and the hour position are flashing OFF and the minute position are flashing the timer icon disappears cancel timer function Timer ...

Page 11: ...hen you press TIME key multiple times until the timer icon disappears Function circulation Press MENU key if it is the 4 way Round way Cassette model you need press MENU key for 5 seconds to enter function circulation use or key to switch between different functions The function circulation is as follows functions that are not valid for some models do not participate in the circulation please refe...

Page 12: ...nter the corresponding function setting interface Humidity setting only valid for part of models Press MENU key you will enter function circulation humidity setting will be displayed first Then press MENU key to enter setting interface at this time you can use or key to adjust humidity parameter The parameter adjustment range is 30 70 Enter into automatic control by pressing when the humidity is 7...

Page 13: ...st the swing angle After adjustment press MENU key to exit the setting 2 After adjustment if there is no operation within 10 seconds or press MODE FAN key it will quit swing setting interface and previous changes are valid Note When the communication protocol which the wired controller adopts is the second version the up down swing and left right swing or only the up down swing is alternative by d...

Page 14: ... the function is successfully set the corresponding icon will be displayed on the main interface 2 Health airflow up down function cannot be set at the same time When the latter function is set the former will be automatically canceled 3 When health airflow up down function is set if you adjust the swing angle the health airflow up down function will be canceled Health airflow up down function onl...

Page 15: ...ons Switch to function the sleeping time will display by the which is on the top left corner Press TIME key to enter sleeping time setting use or key to adjust the sleeping time by 0 5h once the range of sleeping time is from 0 5h to 72h press MENU key to confirm 2 When the sleeping time is up the controller will turn off 3 If the state of the sleeping function is on when you switch to the sleepin...

Page 16: ...e current temperature is displayed in Fahrenheit setting temperature should be adjusted to 60 F in each mode when energy saving function is set currently the parameter in cooling dry mode will be the lowest limit value Then press key for 15s to switch to Celsius the interface will display 16 C when energy saving function is set its lowest limit value of Celsius will be displayed Switch between Fah...

Page 17: ... turned on the adjustment of the setting temperature of the cooling dry heating mode will be limited The energy saving default parameters are 23 C the lowest temperature limit of cooling and dry mode and 26 C the highest temperature limit of heating mode 3 The energy saving parameters can be changed In cooling mode set temperature to 30 C long press FAN key for 5 seconds to enter energy saving par...

Page 18: ...er function circulation use or key to switch between different functions Switch to icon press MENU key again to cancel the display of icon Filter Cleaning 1 Only in heating mode this function is valid in function circulation 2 Press MENU key you will enter function circulation use or key to switch between different functions When it switches to the 10 C heating function 10 C will flash in the temp...

Page 19: ... MENU key to select the air deflector to be set By pressing MENU key you can switch between the air deflector 1 2 3 4 as well as the simultaneous control and which air deflector flashing indicates that it is selected When selecting a certain air deflector you can use or key to adjust its swing angle 3 After adjustment you can press MODE FAN TIME key or wait 10 seconds to exit the settings Four sid...

Page 20: ...nt functions Switch to function then press MENU key again function will be turned on If the function is turned on icon will be displayed in the main interface In the state where the function is turned on if you want to turn it off please enter function circulation and switch to icon then press MENU key and the function will be turned off 3 When the function is turned on if you adjust swing angle t...

Page 21: ...ers and mode combinations is as follows 00 Auto Cooling Dry Fan Heating 01 Heating Cooling Dry Fan 02 Fan Cooling Dry 03 Heating Cooling Dry Fan 04 Fan Heating Cooling 06 Heating Fan 07 Heating 04 06 07 is valid under the third edition communication protocol 3 Fresh Air unit can execute mode setting it will execute the intersection with three modes of Fresh Air unit cooling heating fan mode Note T...

Page 22: ...ent malfunction and the right side of the colon is the historical malfunction And you can also press TIME key to view more historical malfunction information The lower right corner shows the unit number you can use or key to switch it if the controller controls multiple units 3 In the state of viewing malfunction long press TIME key for 10 seconds to clear the current malfunction and a historical ...

Page 23: ...ameter format A Indoor sensor Tai temperature Decimal b Indoor sensor Tc1temperature Decimal C Indoor sensor Tc2 temperature Decimal d Indoor unit PMV opening 2 Decimal E Indoor unit address Hexadecimal F Indoor unit central address Hexadecimal Parameter inquiry 1 Long press MENU key for 10 seconds if it is the 4 way Round way Cassette model the time is 15 seconds to enter unit number setting inte...

Page 24: ...e 2 When controlling Fresh Air unit the controller s main interface will not display and keys in normal state If you want to set child lock function please press area of key first and then press MENU key together for 5 seconds to set cancel child lock Child lock 1 When the controller is turned on press FAN and MENU keys for 5 seconds to enter static pressure interface The parameter of static press...

Page 25: ...ll flash in the temperature area Press MENU key to confirm and the static display of CL indicates that the function is turned on 2 If the state of the CL function is on when you switch to the CL function in the function circulation pressing MENU key to turn it off 3 When the CL function is set if you switch modes or switch ON OFF the CL function will be exit 4 If you set timer or sleeping function...

Page 26: ...tch between OFF Hours of turn on time Minutes of turn on time Hours of turn off time Minutes of turn off time OFF use or key to adjust parameters After adjustment you need to press MENU key to confirm changes 2 When the turn on time you set is up the outdoor unit quiet is turned on and icon will display in the main interface When the turn off time you set is up the outdoor unit quiet is turned off...

Page 27: ...adjustment use or key to adjust parameter to 1 turn on low temperature dehumidification then press MENU key to confirm change At this time you can exit the advanced settings by pressing MODE key 2 After the low temperature dehumidification function is turned on the range of setting temperature in dry mode is 10 C 30 C 3 If you want to cancel this function please change the parameter of A38 to 0 th...

Page 28: ...C to indicate that the function is off Light strip function only valid for part of models 1 After the controller receives the command from the centralized controller It displays the icon At this time all the keys except the ON OFF key are invalid 2 After the controller receives the lock command it displays the icon At this time all keys are invalid 3 In central or lock state backlight is valid pre...

Page 29: ...ion is valid only during collecting ambient temperature of wired controller Temperature compensation 1 After controller is in cooling mode and is turned off long press ON OFF key for 10 seconds to enter forced cooling function At this time controller will be turned on and LL flashes in the middle area to indicate that the forced cooling function is turned on 2 After controller is in heating mode a...

Page 30: ... use or key to switch between different functions When it switch to the dFg icon and off icon flashes press MENU key to change meanwhile return to the main interface 2 Cancellation method Press MENU key you will enter function circulation use or key to switch between different functions When it switch to the dFg icon and on icon flashes press MENU key to change meanwhile return to the main interfa...

Page 31: ... area is flashing Pressing or keys to switch the parameters and pressing the MENU key to confirm 2 In the clock display area 1 means the local VIP is turned on and 0 means the local VIP is turned off 3 If VIP is not set in the external machine system any line controller of internal machine can be set with VIP function if the external machine system has set VIP function only the VIP machine can be ...

Page 32: ...performed 1 ON OFF Mode Fan speed Temperature setting Swing Energy saving Clock function are available 2 parameter inquiry and malfunction inquiry Difference between the function of the Master wired controller and Slave wired controller Operation 5 When switching between VIP and non VIP you need to exit the current Settings and enter again ...

Page 33: ...ient temperature Sw3 ON Collect ambient temperature from PCB of indoor unit OFF OFF Collect ambient temperature from wired controller Sw4 ON Non volatile memory invalid OFF OFF Non volatile memory valid Sw5 ON Old protocol OFF OFF Self adaption Sw6 ON Reserved OFF OFF Reserved Sw7 ON Model with Up Down and Left Right swing OFF OFF Model with Up Down swing Sw8 ON Fresh Air unit OFF OFF Common unit ...

Page 34: ... switch 1 ON OFF station Function Default setting Sw1 ON Reserved OFF OFF Reserved Sw2 ON Not display ambient humidity OFF OFF Display ambient humidity Sw3 ON Reserved OFF OFF Reserved Sw4 ON Reserved OFF OFF Reserved ...

Page 35: ... A B B C C Indoor 1 Polar wire Wire controller Wire controller A A A B B B C C C Polar wire Polar wire Indoor 1 Wire controller Wire controller Wire controller C D A A A A A A B B B B B B C C C C C C Indoor 1 Indoor 2 Indoor N Indoor 15 Indoor 16 master unit Wire controller Wire controller Wire controller Wire controller Wire controller Wire controller Control wiring of wire controller polar Notic...

Page 36: ...olar wire depending on the indoor units please do follow the corresponding indoor unit installation manual s instruction 2 Individual control as shown Figure B One wired controller controls one indoor unit and the indoor unit connects to the wired controller through 3 pieces of polar wire 3 Two wired controllers control one indoor unit as shown Figure C Either one of wired controllers can be set a...

Page 37: ... 328ft 0 3mm2 x3 core shielded wire 22AWG 3wire 100m 328ft and 200m 656ft 0 5mm2 x3 core shielded wire 20AWG 3wire 200m 656ft and 300m 984ft 0 75mm2 x3 core shielded wire 18AWG 3wire Note One side of the shielded sheet of communication wire must be earthed The total length of communication wire cannot exceed 300 meters ...

Page 38: ... Instruction 2 Fix back cover to the holder After that connect communication wire to CON1 port of wired controller Finally put the front cover of wired controller to back cover to complete the installation Press this button to open the back cover of the wired controller Controller Installation ...

Page 39: ...38 C C A CON1 B 3 2 1 B red yellow white A Wired Controller Wiring Instruction ...

Page 40: ...Qingdao Haier Air Conditioner Electric Co Ltd Haier Industrial Park Qianwangang Road Eco Tech Development Zone Qingdao 266555 Shandong P R C ...

Reviews: