MAINTENANCE SERVICE AND TROUBLE SHOOTING
Too much noise in washing
Y
N
Y
Y
Y
Y
N
Y
N
N
N
If the noise of the motor is too much
If the motor fastened tightly
If the noise of the retarder is too much
If the belt is too tight or loose
If the radiating pulley is loose
Replace the retarder
Fasten the motor
Replace the motor
Adjust the belt
Fasten the radiating pulley
Add pulsator gasket
The pulsator is rubbing the bottom of the inner tub
Start the no-water test
program;do no-water washing
Check if
the purple,blue
and yellow legwire of HM
wire are inlayed to the corresponding
1,2,3 terminals of the drain
motor
Measure
the voltage between the 1,2
terminals of the drain
motor
Measure
the voltage between
the purple and blue terminals of
the computer
sequen
Check if
the two paws are
inserted into the two
ratchet
Check if the drain motor works
Check if the paw spring
is unlocked
Check if
the retracting spring of the
retarder is loose
Check if
the gap between
the adjusting screw of the
retarder brake lever and the baffle plate
of the paw connecting arm is
too small
Not exist
Not exist
Replace the retarder
Replace the computer sequencer
Adjust the
connecting arm of
the paw
Adjust the paw spring
Adjust the retracting
spring
Adjust the adjusting
screw of the brake
lever
Exit
Exit
Y
Y
Y
N
N
N
N
Y
Y
N
Y
Inlay the HM wire again
Replace drain motor
Replace the wire unit
At this time please confirm if the drain motor works normally
The tub rotates to one direction(in washing)
N
Summary of Contents for XQBM22-C
Page 18: ...Sincere Forever ...