background image

8

Operation Guide

When the mode selection switch is turned to "        " or "      " ,
the  air conditioner will only blow out air without cooling.

If the mode selection switch is turned from cooling mode to fan

mode, do not turn it back until at least 3 minutes have elapsed.

<1>

<2>

<3>

<4>

<5>

When set to "         ", fan motor runs  at high

speed to blow out strong air.

When set to "         ", fan motor runs  at low speed

to blow out gentle air.

When set to "        ", air conditioner will start

cooling at low speed, blowing out gentle air.

When set to "        ", air conditioner will start

speedy cooling, blowing out strong air.

When set to "      ", air conditioner stops running.

Mode selection switch controls the fan motor

speed and cooling speed.

Hint

When the switch is set to "    ", the indicator lights

up, and vertical louvers will swing from side  to side,

delivering gentle air thus making you feel very

comfortable. When it is set to "     ",  the indicator

goes out, and the vertical louvers stop at any position.

Auto air deflector switch

Mode selection switch

Auto swing

Mode selection

Summary of Contents for THW18C T3

Page 1: ...OPERATION MANUAL Please read this operation manual before using the air conditioner WINDOW TYPE ROOM AIR CONDITIONER No 0010545537 HW 18CE03 HW 18CI13 ...

Page 2: ...structions 4 Preparation 5 Part Names 6 7 Operation Guide 8 9 Maintenance 10 Tips for Energy Saving 11 For Trouble Free Operation 11 Trouble shooting 12 Important Please Read Before Starting 13 Installation Instructions 14 Installation Guide 15 ...

Page 3: ...WARNING Installation Location 3 Cautions WARNING CAUTION We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit Before installation check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate Do not install this air condition...

Page 4: ...sult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner s tubes with sharp or pointed items crushing or twisting any tubes or scraping the coatings off the surfa...

Page 5: ...get damaged prior to being picked up by the waste disposal center and contribute to environmental awareness by insisting on an appropriate antipollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the packaging of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken up or ...

Page 6: ...n lever WAIT 3 MINUTES BEFORE RESTARTING VENTILATOR Mode selection Temp setting Auto swing Front panel Air inlet indoor side Air outlet indoor side Air inlet outdoor side Operation panel Operation cover Air filter WAIT 3 MINUTES BEFORE RESTARTING VENTILATOR Mode selection Temp setting Auto swing MODEL HW 18CE03 ...

Page 7: ...panel Cabinet 7 Machine body Operation panel Mode selection switch Auto swing switch Thermostat switch Ventilation lever WAIT 3 MINUTES BEFORE RESTARTING VENTILATOR Mode selection Temp setting Auto swing WAIT 3 MINUTES BEFORE RESTARTING VENTILATOR Mode selection Temp setting Auto swing MODEL HW 18CI13 ...

Page 8: ...n set to air conditioner will start cooling at low speed blowing out gentle air When set to air conditioner will start speedy cooling blowing out strong air When set to air conditioner stops running Mode selection switch controls the fan motor speed and cooling speed Hint When the switch is set to the indicator lights up and vertical louvers will swing from side to side delivering gentle air thus ...

Page 9: ...running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature Remarks Ventilation Lever When the slide lever is at the position the vent door opens to allow air smoke or odors to be expelled from the room position the vent door is closed and the air inside the room is circulated and conditioned Vertical airflow direction Vertical Airflow Direction ...

Page 10: ...y be used 3 Flush the air filter carefully with clean water after removing the dirt Let it dry completely 1 Put the air filter on 2 Push the part marked PUSH until you hear a click Air filter cleaning Installation of filter Washing air filter PUSH Air inlet PUSH 1 Loose the air filter by pushing PUSH at both ends of air inlet 2 Hold the air filter by frame and lift it forward for approx 5 mm 3 Pul...

Page 11: ...ether the air inlet or outlet has been blocked Go away No entrance Keep away from me For longer and trouble free operation of the unit pay special attention to the following Install the air conditioner at a location strong enough to support the unit Leave enough space around the air inlet and outlet for better circulation Avoid sites where flammable gas leaks Problems may occur if the unit is inst...

Page 12: ...ght into the room Use curtain or blinds Is mode selection switch set to fan mode Are doors or windows left open Shut doors and windows Is there any obstacle blocking air inlet or outlet Remove the obstacle Is the fresh air knob shifted to the right Is there a strong heat source in the room Is air filter clogged Remove and clean If problems cannot be solved please pull out power plug and contact yo...

Page 13: ... properly grounded with a ground or earth wire or through the supply wiring DO NOT under any circumstances cut or remove the third ground prong from the power cord plug DO NOT use an adapter plug or extension cord DO NOT use a damaged power cord plug or wall outlet Replace them immediately DO NOT change the internal wiring or any part of the system DO NOT turn the air conditioner on and off by plu...

Page 14: ...x 1 Applicable ambient temperature range is 21 o C 52 o C 2 If the power supply cord is damaged it must be replaced by the manufacturer the service agent or a similar qualified supplier An extension cord is not recommended 3 The wiring method should comply with local wiring standards 4 After installation the power plug should be easy to access 5 The breaker of the air conditioner should be an all ...

Page 15: ...nditioner from its packing carton 4 Place the air conditioner on the metal support 5 Stuff gaps in the wall or window with soft sponge material or rubber gaskets to block outside noise and keep cool air from escaping Note After finishing the installation of the air conditioner fix the panel board onto the casing with two side attachment screws For HW 18CI13 add one front attachment screw Name Appe...

Reviews: