Page 1: ...HSU 18CI03 T3 No 0010505692 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSU 18C03 T3 HSU 24CI03 T3 SFST24TR3 HSU 18CK03 T3 ...

Page 2: ...terials collecting centers and waste paper disposal services nearest to your house Disposal of the packaging of your new air conditioner Safety Instructions and Warnings 1 Cautions All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper...

Page 3: ...ut fingers or any other things into the inlet outlet and swing louver Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof Remark per EMC Directive 89 336 EEC To prevent flicker impression during the start of the compressor Technical Process and the adversely influence caused by the 2nd harmo...

Page 4: ...g children or infirm persons without supervision 9 Young children should be supervised ensure that they do not play with the appliance 10 The appliance must be installed on strong enough supporter 11 The wiring diagram is attached inside the machine 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire...

Page 5: ... mode indicator Timer mode indicator Power indicator Vertical flap Air filter Inlet grille Emergency switch manual Test running switch manual Use remote controller to adjust up and down air flow Don t adjust it manually Lights up when unit starts Lights up when Timer operation is selected Lights up during compressor running A beeping sound is generated when received a signal from remote controller...

Page 6: ... TIMER OFF display 21 TEMP Used to select your desired temperature 22 FAN Used to select fan speed 23 POWER ON OFF Used for unit start or stop 24 SLEEP Used to select sleep mode 25 SWING 26 SET Used to confirm timer and clock settings 27 HOUR Used to set clock and timer settings NOTE 1 The following functions and related displays are not available AUXILIARY HEAT display POWER SOFT display LOCK dis...

Page 7: ...ay of the remote controller Parts and Functions If the unit which you purchased has not health function remote controller should like the following figure 1 Mode display AUTO COOL DRY FAN 2 SWING display 3 FAN SPEED display 4 HEALTH display 5 SLEEP display 6 LOCK display 7 TIMER ON display 8 AUXILIARY HEAT display 9 SWING 10 MODE Used to select AUTO COOL DRY and FAN 25 SET Used to confirm timer an...

Page 8: ...equest as illustrated Put on the cover again Confirmation indicator In disorderation reload the batteries or load the new batteries after 6 mins Note Use two new same typed batteries when loading If the remote controller can t run normally or doesn t work at all use a sharp pointed item to press the reset key Hint Remove the batteries in case unit won t be in usage for a long period If there are a...

Page 9: ... time remains on LCD All indicators on indoor unit go out Vertical flap closed automatically Hints Remote controller can memorize settings in each operation mode To run it next time just select the operation mode and it will start with the previous setting No reselecting is needed TIMER ON OFF needs reselecting Cautions Note On cooling only unit heating mode is not available The above information ...

Page 10: ...ry time the button is pressed temp setting decreases 1 o C Unit will start running to reach the temp setting on LCD Press FAN button For each press fan speed changes 4 Fan speed selection as follows just press ON OFF button and unit will run in previous status Unit runs at the speed displayed on LCD Hints On cooling only unit heating mode is not available Remote controller can memorize each operat...

Page 11: ...nsumption cut down as well So you d 6 Unit stop Press ON OFF button Only time remains on LCD All indicators on indoor unit go out Vertical flap closes automatically Cautions Unit won t restart until 3 minutes have elapsed due to system protection HEAT mode is not available on cooling only unit It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode otherw...

Page 12: ...ess HOUR button Every time the button is pressed time increases 10 min If button is kept depressed time will change quickly Every time the button is pressed time decreases 10 min If button is kept depressed time will change quickly Time will be shown on LCD It can be adjusted within 24 hours Timer mode indicator on indoor unit lights up 4 Confirming your setting After setting correct time press SE...

Page 13: ... 10 min If button is kept depressed time will change quickly Every time the button is pressed time increases 10 min It can be adjusted within 24 hours Time will be shown on LCD AM refers to morning and PM to afternoon Press HOUR button 4 Time confirming for TIMER ON After time setting press TIMER button to confirm ON stops blinking While OFF starts blinking Time displayed Unit starts at x hour x m...

Page 14: ...unction 3 Press the HEALTH again then the health function stops The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room BRIEF INTRODUCTION TO HEALTH OPERATION ...

Page 15: ... cooling and heating Cooling when the room temperature at the start of operation is above 23 o C temperature is less 16 o C do not use it in the normal Use this switch in the test operation when the room operation operation starts with the air flow speed setting Hi Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the swi...

Page 16: ...t be too Iow for your sleep As shown in Fig l Power Failure Resume Function with the indicator lighting up If the unit is started for the first time the compressor will not start running unless 3 minutes have elapsed When the power resumes after power failure the unit will run automatically the power indicator lights up and 3 minutes later the compressor starts running Note In AUTO mode unit will ...

Page 17: ...cloth Don t use glass cleaner or cloth soaked with chemicals 1 Open inlet grille by pulling it upward Air Filter 2 Remove air filter Push up the filter s center tab slightly until it is caesura of the stopper Remove it by pulling down 3 Clean the filter Use a vacuum cleaner to remove dust or wash the filter with water After washing dry the filter completely in the shade 5 Close the inlet grille 4 ...

Page 18: ...indows during operation Never fail to observe the followings Do not sprinkle water over the unit Do not block the inlet or outlet Do not pull power plug Do not use for other purposes Such as food preservation plant cultivation or animal breeding Avoid time wasteful operation Curtains or blinds for windows Proper temperature Once every two weeks ...

Page 19: ... is generated by refrigerant flowing in the system During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes Should there be a big noise from air flow in unit operation air filter may be too dirty This is because the system circulates smells from the interior air such as the smell of furniture cigarettes During C...