Haier Sea Elephant PJF2-150W User Manual Download Page 7

4

11

To ensure that customers can use water heater properly and safely, we  
seriously inform  customers that you must contact the appointed professional 
serving personnel for installing and service. For any improper installment, our 
company will not burden any responsibility. 

When the power supply is connected, pay attention that connecting lines of 
pump are Inserted stably, and can not run without water. Before any 
maintenance and repair of water heater, please make sure that you Cut off  
the power Supply. Non-professional person are not allowed to adjust and 
maintain water supply.
Before electrification please make sure that machines are full of water, 
otherwise it will cause a system malfunction.  The sockets are subject to 
national standards and are connected to the ground reliably. It is prohibited 
to use water heater without a reliable grounding.
The water heater is equipped with t

. For 

secure use, please do not change installment position personally. The 
evacuating tube nozzle should be downwards vertically and are open to the 
air so as to prohibit jamming the exit. A draining pipe is linked to the 
evacuating tube  nozzle and leads to the sewer opening. (the draining pipe is 
otherwise sold) 
Hot water with a temperature higher than 50

 might result in scalding and 

customers should mix hot water and cold water and then have a shower or 
wash.
In cases when water heater is seriously soaked, it must be checked by 
technical personnel ratified by our company before it is reused.
The hot water in water heater is not suitable for drinking. As a result of long-
term use, scale might be produced in the water tank. Meanwhile, the aging of 
the water pipe can result in a change of water quality. Therefore, when you 
wash rice and vegetables with water in the container, please wash them once 

emperature and pressure valve

When collector equipment is installed, it can not be inversely placed. 
Outdoor and indoor pipeline must use metal pipes.
Solar stage, a infusing liquid valve and expanding  tank must install the 
circulating water-exiting pipe of the tank.
Heat-preserving of pipelines must use specially designed materials by our 
company.

ollector equipment should be installed facing south.

Evacuating opening of the system safety valve should be connected to the 
release opening of sewage.

C

Particular warning Attentions in installment

Use method

 sensor malfunction alarm of water-storing tank (E4), etc. When these 

problems happen, the system will display malfunction code E1~E4. The 

above malfunction protection is non-restorable and therefore, the system can 

only normally run after malfunction is eliminated and the electricity is re-

connected. 

3. Interface indication and instruction for operation

 After the solar water heater center is installed, to confirm that the water-

storing tank is full of water and to check that each pipeline is connected 

properly and not leaking. To check that the power supply of the water-storing 

tank corresponds to the requirements and then to connect power supply.

4. Instruction for controller setting 

A.Turning on/ turning off: the system is turned on directly and automatically 

enters the working mode and conditions before power supply is cut off. The 

first tacitly approved working mode of the system is the solar energy mode. 

The four-number tube of the indication screen displays the clock. The five-

number tube under the screen respectively displays water temperature of 

water-storing tank and the temperature of water-exiting. The indication 

interface is displayed in Fig.9 and at this time, all the pressing keys are 

effective. Then press power supply key and the system will be turned off and 

enter the electricity saving mode. The indication interface is displayed in   

Fig.10 and at this time, only power  supply key is effective and other keys are 

ineffective. The interface only displays water temperature of water-storing 

tank and the temperature of water exiting of collector equipment. However, 

when the system is turned off, the solar heating and malfunction alarm 

protection are all working and only if the conditions for the running of the 

water pump are satisfied, water pump will run at full speed. When malfunction 

alarm appears, it will display malfunction code.

B. Selection of working mode: the system provides four working modes, and 

customers can select any mode as the present working mode.  When the 

system is turned on, press the mode key, and the system will circularly 

exchange in order of solar energy heating, simultaneous heating, preset  

heating and intellectual heating. Meanwhile, the corresponding icon point 

will be on. Press mode key to choose a certain mode and stop pressing mode 

key for 2 seconds, then the system will automatically enter this mode.

C. Parameter setting in all modes: to press the setting key can set the 

followingParameters: clock, preset time, heating temperature, and 

temperature difference value of water pump running. The number tube in the 

set parameter indicates glisteningly. To press the adjusting Key 

    

to

Summary of Contents for Sea Elephant PJF2-150W

Page 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Page 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Page 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Page 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Page 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Page 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Page 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Page 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Page 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Page 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...