Haier Sea Elephant PJF2-150W User Manual Download Page 4

1

1.Home water heater:

Collector equipment is aslant installed  on the rooftop and perfectly integrated 
with building, match  the building standard and fashion nowadays.

2.

Vacuum glass

 tube  is efficient and reliable:

The conductive efficiency of the tube  is supernale. Vacuum tube of collector 
equipment is without water and dirts, antifreeze, high endurance, efficient and 
secure.

3.Selective coat endothermic system

The endothermic system adopts the latest international high-tech. It is 
characterized by high absorbing capacity and low reflectivity.

4.Heat water system of enduring pressure:

Water can be supplied in more than one line. The flux of water is enough to use, 
the usage of  water is comfortable  and  the regulation of water temperature is 
convenient. System run reliably and can be used under all-weather .

5

.scientific designing:

Four kinds of working modes are designed to supply water under different 
season.Control the running of pump automatically according to different 
temperature , enconomizing energy and prolonging life of pump. Possess the 
function of digital display of water temperature and multisafeguard, safe to 
use,easy to use.

14

Electric circuit diagram  

Notes for  usage

 the serving person.
8.When the system runs continually over one month, you are suggested to 

check regularly whether the deviation of the clock is large so as to adjust the 
clock promptly and ensure that the preset and intellectual heating modes 
operate normally.

9.In cases when the power supply line of the appliance is damaged, it is the 

personnel of after service who change that for specially designed lines 
(provided by the manufacturer).

10.In cases when the temperature of water-storing tank exceeds 85

, and the 

electrical enclosure indicates E2.First,you should cut off power supply, 
then,to release a little of hot water and supply some cold water.when the 
temperature of water is decrease and then to connect  power supply ,the 
fault is able to obviate. 

11.The temperature difference for running of circulating water pump suggests 

that the temperature should be chosen as 15 

 in seasons when the 

sunshine is strong(eg, summer), and 10

in seasons when the sunshine is 

weak (eg, winter).

12.When water heater is not used for long and you use it again, to avoid 

occurrence of accidents,you shoud exhaust the system, and the system must 
be full of water before usage,let the gas which lie in the pipe out,meanwhile, 
make sure there is no smoke, fire or other appliances near when you open 
the valve,the exhausting way: open the hot water outlet  and cold water inlet  
valve, when the water come out sustaining after exhausting all the gas, then 
close the hot water outlet valve.  you had better operation the valve in the low 
tempreture,such as wee hours or night, or the life of the system will be 
influenced. to check  all the parts of the system in good condition, and make 
sure the tank full of water, then you can  use it.  

13.Operation exhaust valve termly so as to clear dirty thing, and insured to 

exhaust valve  be not block off.

C o n t r o l l e r
Display Board

L:
N:
E:  
K1

K2

R

EH:H
MT:High 
RT1:T
RT2:C

  Brown  Wire

  Blue  Wire 

YelloW/Green  Wire 

elay

eating Element

Temperature Limiter

ank Temperature Sensor

ollector Temperature Sensor

RT1

RT2

K1

K2

Pump

E

L

N

C o n t r o l l e r
Wire Board

le

a

k

a

g

e

 I

n

s

_

P

e

c

tio

n

 L

o

o

p

Summary of Contents for Sea Elephant PJF2-150W

Page 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Page 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Page 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Page 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Page 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Page 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Page 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Page 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Page 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Page 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...