Dimension 

3

Installation

Installation

(Figure 1)

A Cold water inlet
B Hot water outlet
C Heating element

Enamel tank

Magnesium anode rod

Front view

Side view

Cutaway view

Model

FCD-30

Volume

  

Net

weight

a1

c1

30L

440mm

503mm

100mm

375mm

   

16 kg

d1

b1

Remarks:the permitted error limit of above parameters is

10%. 

Connection and use of safety valve (see to Figure 4) :

The safety valve should be connected to the cold water inlet pipe. Please check carefully 

if the direction is correct after installation. The correct direction of installation is that the 

arrowhead on the safety valve should be pointed to the water heater.

Please connect the drain hose to the safety valve. Connect one end of the hose to the 

safety valve vent and the other end to the sewage drain. The hose can be cut short or 

extended as necessary. The hose shall be installed as inclined downward.

The water may drip from the discharge pipe of the pressure relied device and that this 

pipe must be installed in a continuously downward direction and in a frost-free 

environment. Check safety valve once a month as follow: move the small handle of safety 

valve, if there's water flowing out, safety valve is normal; if there's no water flow, please 

contact local after-sales service station.

The pressure relief device is to be operated regularly to remove lime deposits and to 

verify that it is not blocked.

Installation must be made by installers of or designated by our company after-service 

department. The water heater shall be wall-mounted.

Before installation, first decide the installation location according to the usage 

requirement. Make two holes in the wall depth 70 mm and 

9 mm by chum drill as per 

the indication of installation diagram. Fasten the wall-mounting plate on the wall tightly 

with two expansion bolts as per indicated in Figure 2. Check and confirm that the bolts  

are not loose. Hang the water heater vertically onto the wall by the wall-mounting plate. 

Confirm it is firmly mounted. Install accessories such as safety valve, drain hose as 

shown in Figure 4. Use sealing compound to prevent water leakage.

To facilitate installation and removal, it is suggested a G 1/2" movable nut is fitted at 

appropriate locations on inlet and outlet pipes respectively. Find water supply location. 

Connect inlet pipe, outlet pipe and city water pipe respectively to the use point. 

The hot water pipe shall not be too long to reduce the heat losses.

Please reserve some space in installation for the future maintenance.

(Figure 2)

Wall-mounting plate

Expansion bolt

(Figure 3)

Connect to drain hose

b1

c1

A

B

d1

a1

C

D

E

Attentions in Installation

City water inlet pressure shall not be less than 0.05 MPa.

Electric water heater shall be installed indoors with ambient temperature above 0

. The 

pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In 

case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.

The mounting wall shall be firm and reliable to support twice the weight of water heater 

full of water. Non-load bearing walls or air brick walls must have corresponding protective 

measures like additional support, wall-through screws or back boards. 

Electric water heater shall be located in a place easy for use, maintenance and with a 

floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be 

damaged. The installation location shall avoid being above toilet bowl, bathtub, 

washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.

Power socket for water heater shall be in a dry place free of water splash. (splash-proof 

box is preferred)

Cold water inlet

Mixing 
 valve

 Hot water
outlet valve

Cold water
outlet valve

Shower 
 nozzle

 Hot
water
outlet

Safety valve

For reference in installation only

(Figure 4) 

Reviews: