background image

USERS OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BUILT-IN GAS COOKING HOBS

Summary of Contents for JZT-QHA9331P

Page 1: ... 小 微 各 部 门 会 签 版式设计 版式审核 会签意见 共 条 明细如下 项目负责人签字 批准 签字 签字 共 条 明细如下 委托人落实意见 印刷说明 1 纸张大小 A5 2 纸张材质 70g 双木浆纸 3 装订 排版印刷后中间钉2个书钉 4 需经技术部封样后供货 5 Supplier number V 由供货工厂排版时填写V代码 专用号 0220500488 替换单编号 设计时间 2018 05 11 版号 第 1 版 巴基斯坦项目JZT QHA9331P ...

Page 2: ...USERS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT IN GAS COOKING HOBS ...

Page 3: ...Please preserve this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for the task it has explicitly been designed for that is for cooking foodstuffs Any other form of usage is to be considered as inappropriate and therefore dangerous The manufacturer declines all responsibi...

Page 4: ...n with some components although these parts are within the limits allowed by the norms The complete safety of the appliance also depends on the correct use we therefore recommend to always pay a extreme attention while using the product especially in the presence of children After having unpacked the appliance check to ensure that it is not damaged In case of doubt do not use it and consult your s...

Page 5: ...liances The various components of the appliance are recyclable Dispose of them in accordance with the regulations in force in your country If the appliance is to be scrapped remove the power cord After use ensure that the knobs are in the off position Children less than 8 years of age shall be kept away unless continuously supervised This appliance can be used by children aged from 8 years and abo...

Page 6: ...roduct category However special care should be taken around the underneath of the appliance as this area is not designed or intended to be touched and may contain sharp or rough edges that may cause injury CAUTION The cooking process has to be supervised A short term cooking process has to be supervised continuously If the power supply cable is damaged it must be replaced only by an authorized ser...

Page 7: ...6 Fig 1 1 Model JZT QHA9331P 12T FEATURES AND TECHNICAL DATA 1 1 7 8 9 1 4 5 6 2 3 ...

Page 8: ...ding to the laboratory test data the DRY PIRE PROTECTION device will cut off the gas vavle and make buzzer Alarm about 20 seconds to avoid gas leakage and safety accidents Please make sure that the pot bottom and the t o p o f sensor are in effective touching otherwise the DRY FIRE PROTECTION function can t work properly the function will start within a few minutes when the h e a t i n g water in ...

Page 9: ...ation by LOW BATTERY INDICATION FUCTION IMPORTANT When the battery voltage is too low to ensure the DRY FIRE FUNCTION to work normally the hob will alarm about 10 seconds to remind you to change the battery in time In this case it cann t be ignited by the left burner but it can be ignited by other burner without DRY FIRE FUNCTION After using the gas hob or the protection function working to cut ou...

Page 10: ...ever between the maximum aperture and closed positions IMPORTANT Fig 2 1 HOW TO USE THE COOKTOP 2 N B When the cooktop is not being used set the gas knobs to their closed positions and also close the cock valve on the gas bottle or the main gas supply line Caution The cooking hob becomes very hot during operation Keep children well out of reach Caution Do not cover the hob with aluminium foils To ...

Page 11: ...r some reason the safety valve will automatically stop the gas flow To re light the burner return the knob to the closed position wait for at least 1 minute and then repeat the lighting procedure LIGHTING THE BURNERS Firstly install two pcs of No 1 batteries in the battery box at the bottom of the gas hob and then perform the ignition and fire size adjustment according to the order of illustration...

Page 12: ...andle 1 handle 2 fixed plate fixed hole When the flame is in poor condition adjust the handle at the bottom of the hob to increace or reduce air amount illustrated in fig 2 4 fig 2 5 and fig 2 6 in order to combust completely When the flame is long and yellow incompletele combustion flame turn clockwise to adjust the handle to ncrease the amount of air intake according to the position shown in the...

Page 13: ...ON FUNCTION to start and cut off the gas valve Therefore these should be cooked on the right burner because of above cause After the hob alarms for the low power please change two new batteries in time If you don t change them the hob can still ignite normally but the DRY FIRE PROTECTION FUNCTION can t work as normal due to the low power DRY FIRE PROTECTION FUNCTION is not completely intelligent p...

Page 14: ...e high output of the burners and therefore energy waste A small pot on a large burner does not give you a boiling point in a shorter amount of time since the capacity of heat absorption of a liquid mass depends on the volume and the surface of the pot Fig 2 9 Ultra Rapid Left and right in fig 1 1 The suitable burner must be chosen according to the diameter and the capacity used As an indication th...

Page 15: ...itable products to clean the appliance WARNING When correctly installed your product meets all safety requirements laid down for this type of product category However special care should be taken around the underneath of the appliance as this area is not designed or intended to be touched and may contain sharp or rough edges that may cause injury ENAMELLED SURFACES All the enamelled parts must be ...

Page 16: ...fig 3 1 next to each burner is are always clean to ensure correc operation of the safety valves PAINTED PARTS AND SILKSCREEN PRINTED SURFACES Clean using an appropriate product Always dry thoroughly IMPORTANT these parts must be cleaned very carefully to avoid scratching and abrasion You are advised to use a soft cloth and neutral soap CAUTION Do not use abrasive substances or non neutral detergen...

Page 17: ... 3 1 1 1 6 9 2 10 3 11 6 7 8 9 10 11 12 2 3 4 5 pan support inner burner outer burner 4 senser 5 12 dual burner crown 7 single burner 8 single burner crown 13 15 ignition electrode G 14 16 probe P 15 16 14 13 ...

Page 18: ... current local regulations in force and in observation of the instructions supplied by the manufacturer Failure to comply with this condition will render the guarantee invalid The appliance must be installed in compliance with regulations in force in your country and in observation of the manufacturer s instructions Installation technicians must comply to current laws in force concerning ventilati...

Page 19: ... edges that may cause injury 650 700mm 500 mm 450 mm Fig 4 1b Fig 4 1a Gas hob installed G 100mm Space for connections Clearance Door Thermal protection barrier The thermal protection barrier must be removable with the use of a tool for installation and service heat resistant made from low thermal conductivity material Fig 4 1c D G E F A C B Measures mm Description A B C D E F minimum G minimum JZ...

Page 20: ...outside When these openings cannot be made the necessary air can come from an adjacent room which is ventilated as required as long as it is not a bed room or a danger area in compliance with appliance local regulations In this case the kitchen door must allow the passage of the air Extractor hoods connected directly to the outside must be provided to allow the products of combustion of the gas ap...

Page 21: ...rning gas and electrical installations Failure to install the appliance correctly could invalidate any manufacturer s warranty This appliance is supplied for use on NATURAL GAS NG 2000 Pa check the gas regulation label attached on the appliance The gas connection must be carried out by an authorised person according to the relevant local standards If using a flexible hose make sure it does not com...

Page 22: ...le 1 2 G Cylindrical Appliance inlet pipe Floating nut included in the rigid pipe or flexible hose Rigid pipe or Flexible hose included Gasket not supplied Gasket Hose holder Hose clamp Rubber hose not supplied installed before leaving factory ...

Page 23: ... with a surface temperature of 70 or above or refer to applicable local regulations the hose is not subject to excessive heat by direct exposure to flue products or by contact with hot surfaces the hose can easily be inspected along its entire length to check its condition the hose is replaced at the printed due date marked on the hose itself or if it shows signs of wear or damage and replaced reg...

Page 24: ...is not longer than 2000 mm or refer to applicable lacal regulations and does not come into contact with sharp edges corners or moving parts as these may cause abrasion Use a single flexible hose only neverconnect the appliance with more than one flexible hose the flexible hose can easily be inspected along its entire length to check its condition if it has an expiry date it should be replaced befo...

Page 25: ...24 Part number 0220500488 Supplier number V ...

Reviews: