the power supply cord

and so on.

2.Do not install in the place where there is any

possibility of inflammable gas leakage around the unit.

3.Do not get the unit exposed

to vapor or oil steam.

Cautions

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works

may cause electric shock, fire, water leakage.

Connect the earth

cable.

earthing

WARNING

When abnormality such as burnt-small found,

 immediately stop the operation button and

contact sales shop.

OFF

Use an exclusive 

power source

with a circuit 

breaker

ENFORCEMENT

Connect power supply cord

to the outlet completely

Use the proper voltage

Do not use power supply 

cord in a bundle.

Take care not to damage

the power supply cord.

1.Do not use power supply cord extended

or connected in halfway

STRICT

ENFORCEMENT

STRICT

STRICT

ENFORCEMENT

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

operation by disconnecting

Do not channel the air flow directly

at people, especially at infants or

the aged.

Do not try to repair or 

reconstruct by yourself.

Do not use for the purpose of storage of

food, art work, precise equipment,

breeding, or cultivation.

CAUTION

Take fresh air occasionally especially

when gas appliance is running at the

same time.

PROHIBITION

STRICT

ENFORCEMENT

Do not operate the switch with

wet hand.

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

Do not install the unit near a fireplace

or other heating apparatus.

Check good condition of the

installation stand

Do not pour water onto the unit

for cleaning

PROHIBITION

Do not place animals or plants in

the direct path of the air flow

Do not place any objects on or

climb on the unit.

Do not place flower vase or water

containers on the top of the unit.

Do not insert objects into the air

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

    STRICT

ENFORCEMENT

Check proper

installation of  the

drainage securely

WARNING

Summary of Contents for IKI-09

Page 1: ...ENGLISH USER S MANUAL AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT MODELS IKI 09 IKO 09 IKI 12 IKO 12 IKI 18 IKO 18 IKI 24 IKO 24...

Page 2: ...ntacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage exp...

Page 3: ...12 4 5 11 8 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING 13...

Page 4: ...lay TIMER ON display 7 TEMP display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to press this button to...

Page 5: ...ilable in FAN mode And temp setting is disabled In FAN mode sleep operation is not available Emergency Operation Use this operation only when the remote controller is defective or lost and with functi...

Page 6: ...ion will be cancelled Press button to enter additional options when cycle display to will flash and then press enter to power function When cancel the function please enter additional options again an...

Page 7: ...a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this...

Page 8: ...not disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough spac...

Page 9: ...rst fixed for the Making a Hole on the Wall and Fitting the Piping Hole Cover Drawing of pipe Installation of the Indoor Unit Rear piping Draw pipes and the drain hose then fasten them with the adhes...

Page 10: ...or due to wiring error Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusi...

Page 11: ...indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter...

Page 12: ...BITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or...

Page 13: ...y cord is damaged it must be replaced manufacturer qualified person 4 The wiring method should be in line with the local wiring 5 After installation the power plug should be easily reached 6 The waste...

Page 14: ...1 2m2 8 H07RN F 3mm R32 A R32...

Page 15: ...24 16 17 23 20 25...

Page 16: ...18 POWER ON OFF 19 DRY 20 TEMP 21 SWING 22 HOUR 23 EXTRA FUNCTION 1 2 24 CANCEL CONFIRM CANCEL CONFIRM 25 RESET RESET 1 2 3 SWING 4 FAN SPEED 5 LOCK 6 TIMER OFF TIMER ON 7 TEMP 1 2 2 R 03 3 4 7m 1 2 3...

Page 17: ...P 1 C 4 FAN To AUTO 2 4 3 2 3 4 COOL DRY 1 1 COOL DRY AUTO 2 3 4 5 AUTO AUTO AUTO COOL DRY DRY 2 C LOW FAN HEAT HEAT AUTO FAN FAN COOL HEAT FAN AUTO SLEEP FAN 16 C 5 Hi TIMER DRY TIMER 23 C 26 C AUTO...

Page 18: ...2 HEAT 1 SLEEP 2 C 1 2 C 3 1 C 3 4 FAN SLEEP 5 TIMER TIMER POWER QUIET HEALTH 1 POWER 2 QUIET QUIET QUIET QUIET QUIET POWER HEAT COOL QUIET 3 AUTO HEALTH HEALTH HEALTH 1 1 2 3 3 O C 2O C 1 O C SLEEP...

Page 19: ...FF TIMER ON OFF OFF 3 12 0 5 12 1 12 0 5 12 1 24 4 OFF 5 TIMER TIMER TIMER OFF Start Stop Stop Start 230V CE 2014 35 2014 30 ROHS 2011 65 RoHS WEEE 2012 19 R32 GWP 675 GWP 1 2 1 2 A C D F 1 2 3 1 2 3...

Page 20: ...20 17 22 26 17 19 26 FC R32 15 10 10 2m...

Page 21: ...2 60 mm 3 l 1 2 3 4 60mm G A 150mm C 120mm C 113mm B 60mm A 70mm B 60mm B 60mm B 60mm 30mm 45mm 45mm 30mm 35mm 35mm B 60mm B 60mm A 120mm C 80mm A 130mm C 110mm 35mm 35mm B 60mm B 60mm IKI 09 IKI 12...

Page 22: ...22 R410A A 0 0 5 mm 1 0 1 5 mm 1 5 2 0mm 1 2 3 4 5 1 2 4G1 00mm2 1 H07RN F 2 T 3 15A 250VAC 3 4 5 3mm 5 6 7 A 8 A 1 PCB 2 4 EEPROM EEPROM EEPROM PCB 7 14 PCB 9 E...

Page 23: ...23 40 C 1 2 3 4 FRONT stopper 5 1 2 4 5 l 6 l l 3 OFF M...

Page 24: ...24 1 2 3 OFF...

Page 25: ...RY dry DRY 2o C 15 T 1 D B W B 32 C 23 C D B W B 21 C 15 D B W 46 26 C D B 15 C D B 27 C D B 15 C D B W B 24 C 18 C D B W B 7 C 8 C INVERTER D B W B 24 C 18 C D B 15 C 2 3 3 15 250V T 25A 250V 4 5 6 7...

Page 26: ...211 300 3300...

Page 27: ......

Page 28: ......

Reviews: