background image

10

Control panel

•HZY-8Z

•HZY-15Z

7

Please observe the following rules when conducting initial start-up and continuous running:

Connect the power cord to the dedicated socket of proper specification when the cooler is empty.

This Transport cooler is preset to run at below 4 ±2

 before factory delivery, so there is no need 

to set up the temperature.If you need to adjust the temperature, please contact professionals for 

operation.

The sound alarm will ring under overtemperature after power-on and this is normal.At this time, 

press any key (press Function or Return key of cold chain module) and the buzzer alarm sound 

will be cancelled.If the alarm condition is not relieved after the default 30 minutes, the sound 

alarm will work again until the temperature sensor reaches the range of 2-10 

.

The temperature can be stabilized within the set temperature range only after the Transport 

cooler has been running for a period of time.

Start putting articles gradually into the transport cooler after completing a thorough inspection of 

the Transport cooler.

Initial power-on

Summary of Contents for HZY-15Z

Page 1: ...icate of Quality checker Transport cooler Operation Manual Model HZY 8Z HZY 15Z Please read this manual carefully before using Our company reserves the right to interpret the operation manual The appearance of product is subject to material object Please keep it properly with the invoice after reading This product is subject to technology or software upgrade without further notice Translation of t...

Page 2: ...thod of Use 11 Maintenance 12 Q A 13 Wiring diagram 14 Specifications 15 17 Name HZY 8Z Operating manual 1 Installation confirmation letter 1 Warranty certificate 1 Plastic bag 1 Power adapter 1 Name HZY 15Z Operating manual 1 Installation confirmation letter 1 Warranty certificate 1 Plastic bag 1 Power adapter 1 Packing list ...

Page 3: ...ly install an automatic manostat suitable for electromotor load If it is required to lengthen the power cord the section area of the lengthened cord must not be less than 2mm2 and the length shall not be longer than 3m Otherwise a fire or electric shock may possibly be caused The power cord of this refrigerator is provided with a three wire grounding wire plug complying with the standard 10A three...

Page 4: ...ner in accordance with current local laws and regulations Do not store corrosive articles such as acid alkali etc in the Transport cooler Otherwise it may cause damage to the internal components or electric parts of the Transport cooler Do not place the packing plastic bags at the locations where children can easily take as plastic bags may possibly cause occurrence of suffocation accident Do not ...

Page 5: ...mperature in the central part of the Transport cooler but it will gradually approach to the true temperature Use the diluted neutral detergent to clean the refrigerator Do not use brushes acid gasoline soap powder polishing powder or hot water to clean the Transport cooler as the above mentioned materials may damage the painting surface as well as the plastic and rubber parts and components Take p...

Page 6: ...rs to a wide range of possible symptoms and corresponding solutions If the problems remain unsolved after operation please contact Haier for after sale service Please do not maintain and disassemble the Transport cooler by yourself Fault Trouble shooting scheme The Transport cooler is not working Check if the input power supply complies with the requirement Whether the plug and socket are in poor ...

Page 7: ...ns It cannot be installed in a narrow small and airtight space It shall at least be guaranteed that the product can be moved in out normally so as to avoid any maintenance difficulty and failure The failure of in time repair may cause damage to the stored articles The ground at the installation place shall be solid and flat The place shall be well ventilated without exposure to direct sunshine Do ...

Page 8: ...y for 10s and the temperature display window in the left box shows the St Press the Set key again and it displays the setting temperature value Press the or key to adjust setting temperature value After completion and 10s no operation the system saves the set temperature value and automatically exits the main interface Power failure prompt function After the power is cut off the brightness of the ...

Page 9: ...sound alarm will ring under overtemperature after power on and this is normal At this time press any key press Function or Return key of cold chain module and the buzzer alarm sound will be cancelled If the alarm condition is not relieved after the default 30 minutes the sound alarm will work again until the temperature sensor reaches the range of 2 10 The temperature can be stabilized within the ...

Page 10: ...re the transport cooler will continue to operate according to the set parameters before the last power failure Pull out the power plug when the Transport cooler will be out of service for a long time so as to prevent electric shock leakage of electricity or fire due to aging of the power cord If the Transport cooler is left unused for a long time in an unattended area make sure that children will ...

Reviews: