background image

2

Do not ground the Transport cooler via gas pipe, power supply conduit, telephone line or 

lightning rod. The abovementioned grounding connection may cause an electric shock or other 

dangers.

Do not contact any electric parts or any switches such as power plug and so forth with a wet 

hand. Otherwise, an electric shock may possibly be caused.
When pulling out a plug from the power socket, hold the power plug firmly but do not pull the 

wire of the power plug. If you pull the electric cord by hand,it may possibly cause an electric 

shock or lead to a fire due to short circuit.
If the Transport cooler runs out of order, please pull out the power plug. Continuous running in 

an abnormal condition may cause an electric shock or fire.
Users must not remove, repair or refit the Transport cooler by themselves. Otherwise, a fire or 

personal injury due to improper operation may possibly be caused.
Before conducting any repair or maintenance of the refrigerator, make sure to disconnect the 

power of the Transport cooler for fear of electric shock or personal injury.
Make sure not to suck in medicine or suspended particles inside and surrounding the Transport 

cooler in time of repair and maintenance. Otherwise, they may possibly bring hazard to your 

health.

When storing toxic, hazardous or radioactive articles, please use the Transport cooler in a safe 

zone. If used improperly, it may bring damage to physical health or environment.
Pull the plug of Transport cooler when it will be out of service for a long time, so as to prevent 

electric shock, leakage of electricity, or fire due to the aging of the power cord.
If the Transport cooler is left unused for a long time in an unattended area, make sure that 

children will not approach the Transport cooler and the box door cannot be closed completely.
Disposal of the discarded Transport cooler shall be conducted by relevant persons. This 

equipment contains reusable materials and shall be disposed of properly - not simply discarded 

with unclassified household waste. Appliances that are no longer to be used must be disposed 

of in a professional and appropriate manner in accordance with current local laws and 

regulations.

Do not store corrosive articles such as acid, alkali etc. in the Transport cooler. Otherwise, it may 

cause damage to the internal components or electric parts of the Transport cooler.
Do not place the packing plastic bags at the locations where children can easily take as plastic 

bags may possibly cause occurrence of suffocation accident.
Do not climb onto the Transport cooler or place articles on it. Otherwise, personal injury or 

damage of Transport cooler may be caused due to the overturn of the Transport cooler.
Do not insert any metal objects like iron nails, iron wire into any orifice and gap or any air vent 

used for internal air circulation of the Transport cooler. Otherwise, it may cause an electric 

shock or injury due to contact of the above objects with the moving parts.
When restarting the Transport cooler after a power failure or power-off, it is required to check 

the setting of the Transport cooler.Change of settings may cause damage to the articles stored.
Put on your gloves at time of maintenance so as not to bump the sharp edges or corners, which 

may result in personal injury.
When moving the Transport cooler, please be careful not to trip over it, preventing damage to 

the Transport cooler or casualties.
Do not use any electric appliance in the store-room of the Transport cooler except for the types 

that the manufacturer recommended for use.

15

Specifications

Name

Transport cooler

Model

HZY-8Z

External dimensions

 (W x D x H)

 (mm)

300×265×260

Internal dimensions

 (W x D x H) 

(mm)

230×140×170

Insulating material

High-density foam

Cooling mode

Semiconductor active refrigeration

Casing/liner

ABS/aluminum plate

Temperature control mode

Computer control system

Net weight

3.5kg

Range of temperature in storage/transport

2

 ~6

 /2

 ~10

Rated power supply

220V (can be connected to 12V cigarette 

lighting plug)

Rated power

60W

Alarm type

Overtemperature alarm, sensor fault alarm 

and power off alarm

Power-off temperature keeping time

2 hours (at 28°C environmental temperature 

with load)

Chargeable battery

Chargeable lithium battery

Production date/Software release version

See bar code on the case body/V1

Note: Our company pays attention to technological innovation. Products are subject to upgrade 

without further notice.

Specifications

Summary of Contents for HZY-15Z

Page 1: ...icate of Quality checker Transport cooler Operation Manual Model HZY 8Z HZY 15Z Please read this manual carefully before using Our company reserves the right to interpret the operation manual The appearance of product is subject to material object Please keep it properly with the invoice after reading This product is subject to technology or software upgrade without further notice Translation of t...

Page 2: ...thod of Use 11 Maintenance 12 Q A 13 Wiring diagram 14 Specifications 15 17 Name HZY 8Z Operating manual 1 Installation confirmation letter 1 Warranty certificate 1 Plastic bag 1 Power adapter 1 Name HZY 15Z Operating manual 1 Installation confirmation letter 1 Warranty certificate 1 Plastic bag 1 Power adapter 1 Packing list ...

Page 3: ...ly install an automatic manostat suitable for electromotor load If it is required to lengthen the power cord the section area of the lengthened cord must not be less than 2mm2 and the length shall not be longer than 3m Otherwise a fire or electric shock may possibly be caused The power cord of this refrigerator is provided with a three wire grounding wire plug complying with the standard 10A three...

Page 4: ...ner in accordance with current local laws and regulations Do not store corrosive articles such as acid alkali etc in the Transport cooler Otherwise it may cause damage to the internal components or electric parts of the Transport cooler Do not place the packing plastic bags at the locations where children can easily take as plastic bags may possibly cause occurrence of suffocation accident Do not ...

Page 5: ...mperature in the central part of the Transport cooler but it will gradually approach to the true temperature Use the diluted neutral detergent to clean the refrigerator Do not use brushes acid gasoline soap powder polishing powder or hot water to clean the Transport cooler as the above mentioned materials may damage the painting surface as well as the plastic and rubber parts and components Take p...

Page 6: ...rs to a wide range of possible symptoms and corresponding solutions If the problems remain unsolved after operation please contact Haier for after sale service Please do not maintain and disassemble the Transport cooler by yourself Fault Trouble shooting scheme The Transport cooler is not working Check if the input power supply complies with the requirement Whether the plug and socket are in poor ...

Page 7: ...ns It cannot be installed in a narrow small and airtight space It shall at least be guaranteed that the product can be moved in out normally so as to avoid any maintenance difficulty and failure The failure of in time repair may cause damage to the stored articles The ground at the installation place shall be solid and flat The place shall be well ventilated without exposure to direct sunshine Do ...

Page 8: ...y for 10s and the temperature display window in the left box shows the St Press the Set key again and it displays the setting temperature value Press the or key to adjust setting temperature value After completion and 10s no operation the system saves the set temperature value and automatically exits the main interface Power failure prompt function After the power is cut off the brightness of the ...

Page 9: ...sound alarm will ring under overtemperature after power on and this is normal At this time press any key press Function or Return key of cold chain module and the buzzer alarm sound will be cancelled If the alarm condition is not relieved after the default 30 minutes the sound alarm will work again until the temperature sensor reaches the range of 2 10 The temperature can be stabilized within the ...

Page 10: ...re the transport cooler will continue to operate according to the set parameters before the last power failure Pull out the power plug when the Transport cooler will be out of service for a long time so as to prevent electric shock leakage of electricity or fire due to aging of the power cord If the Transport cooler is left unused for a long time in an unattended area make sure that children will ...

Reviews: