Installation Instruction
The following must be noted
Electrical connection
The appliance is fitted with a plug and must only be connected
to a properly installed earthed socket. Only a qualified
electrician who takes the appropriate regulations into account
may install the socket or replace the connecting cable. If the
plug is no longer accessible following installation, an all-pole
isolating switch must be present on the installation side with a
contact gap of at least 3 mm. Contact protection must be
ensured by the installation.
Fitted units
The installation cabinet must not have a back panel behind the
appliance. Minimum installation height: 850 mm.
Ventilation slots and intakes must not be covered.
Installing the oven - Fig. 2
Note:
Do not trap or kink the mains lead.
GB
13