Service Manual
Model No:HW60-1281S/1081
Issue
Rev.
14
Error message: Temperature sensor is not properly connected or
damaged (display at the end of a program).
Check if drain pump acts by touching
pump position
Cut off the power and choose spin
program to start, then check the
import voltage of drain pump, is it
between AC 220-240V?
Cut off power and pull out water level
pressure switch wire connection. Set
spin program to start. Check the
export voltage to drain pump, is it
between AC 220-240V?
Check if drain pump or drain pipe is
jammed, and open the filter and clean
Replace drain pump
The wire between PCB and drain
pump is not connected properly.
Replace the wire
Replace PCB
Cut off power and measure the
resistance of temperature sensor by
Check if NTC is connected properly
Check the two black wires of NTC,
are they connected well?
Disconnect the two black wires from
PCB, and measure if the resistance
between the two black wires of PCB
is it infinite?
Replace PCB
NTC exist open circuit .Replace it
Connect NTC well
Connect all wires well
Replace the wire.