HSU09/12XHK-SM
Codes and Description
Domestic Air Conditioner
34
NO
YES
YES
NO
YES
NO
YES
whether terminal CN8
and CN9 on indoor PCB
well inserted or not?
Pull out and reinsert the terminals
Electrify the machine again and turn it on in the cooling
operation
Measure whether there is voltage 60VAC-115VAC
between the red wire and the black wire of Terminal CN9
on the indoor mainboard.
NO
the indoor mainboard is damaged and need replace
Check whether motor can run when turn on the unit
the indoor motor is damaged and need replace
When fan motor is running Measure whether there is
voltage pulse between the middle wire and the black side
wire of Terminal CN8 on the indoor mainboard.
the motor of the indoor unit is damaged and need
replace
the indoor mainboard is damaged and need replace
Summary of Contents for HSU12XHK
Page 42: ...HSU09 12XHK SM 39 9 1 1...
Page 43: ...HSU09 12XHK SM 40...
Page 45: ...three two Removal Procedure HOOKS HSU09 12XHK SM 42...
Page 46: ...1 3 Removal of horizontal flap flap flap flap flap Removal Procedure 43 HSU09 12XHK SM...
Page 47: ...Removal Procedure 1 4 44 HSU09 12XHK SM...
Page 48: ...1 5 Removal Procedure 45 HSU09 12XHK SM...
Page 49: ...1 6 Removal Procedure 46 HSU09 12XHK SM...
Page 50: ...1 7 Removal Procedure 47 HSU09 12XHK SM...
Page 51: ...Removal Procedure 48 HSU09 12XHK SM...
Page 52: ...1 8 Removal Procedure 49 HSU09 12XHK SM...
Page 53: ...Removal Procedure 50 HSU09 12XHK SM...
Page 54: ...9 2 1 Outdoor panel 51 HSU09 12XHK SM 9 2 Outdoor unit...
Page 55: ...52 HSU09 12XHK SM...
Page 56: ...53 HSU09 12XHK SM...
Page 57: ...54 HSU09 12XHK SM...
Page 58: ...55 9 2 2 HSU09 12XHK SM...
Page 59: ...56 9 2 3 HSU09 12XHK SM...
Page 60: ...57 9 2 4 HSU09 12XHK SM...
Page 61: ...58 HSU09 12XHK SM...
Page 62: ...59 9 2 5 HSU09 12XHK SM...
Page 63: ...60 HSU09 12XHK SM...
Page 64: ...10 Appendix x i d n e p p A6 61 10 1 Piping Diagrams HSU09 12XHK SM...
Page 71: ...Cui Wenjuan Wang Fei Wu Hongjin Guo Liang HSU09 12XHK SM...