HSU12
HG(DB)-SM
Wiring Diagrams
27
Domestic Air Conditioner
5.2.5.6 The frequency limitation of modification rate
In the field which is controlled by high frequency, if the modification rate is not high enough, the
control-driven chip will enter into weak magnetic control, this will help to relieve the problem of
modification rate. If during the course of weak magnetic control, the modification rate is still not high
enough, enter into the control of decreasing frequency until the alarm of modification rate is relieved.
5.2.5.7 Temperature protection of the outdoor refrigerating coil
When the defrosting temperature and the sensor’s temperature are higher than 65
ć
, the frequency of
the compressor decreases 1hz/10seconds. Keep the frequency until it decreases to the lowest
frequency. When the temperatures are lower than 65
ć
and higher than 60
ć
, keep the frequency of
the compressor. When the temperatures are lower than 60
ć
, relieve the defrosting temperature
protection.
5.2.5.8
˖
Malfunction display and malfunction handling
a)
ǃ
For the complete appliance’s malfunctions
˖
If there’s malfunction with the outdoor unit, the light of the outdoor unit will flash and its frequency is
1HZ, the number of times is according to the table, when a round of flashing is finished, the light
shoud be off for 5 seconds.
b)
ǃ
For the units’ malfunctins
˖
Annex 1
If there’s malfunction with the units, this will not affect the run of the complete appliance, but this can
be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of times is
according to the malfunction table of the indoor units. When a round of flashing is finished, the light
shoud be off for 10 seconds. Then report according to the order : unit A
ė
unit B
ė
unit C
ė
unit D, that
is, if there’s malfunction with several units, then just report the indoor unit with the highest priority level.
Among the unit malfunctions, the priority level of the communication malfunction is the highest, for
others, that appears first will have the priority.
Remarks: in 3 minutes when the compressor stops, the units’ malfunctions are not displayed; the
complete appliance’s malfunctions are prior to the units’ malfunctions.
Annex 1
˖
Malfunction codes of the whole unit
Remarks: under the mode of refrigeration, the malfunctions of each unit’s thin pipe temperature
sensor are not reported, under the mode of heating, the malfunctions of each unit’s thick pipe
temperature sensor are not reported.
F12
1
Outdoor EEPROM error
F1
2
The protection of IPM
F22
3
Overcurrent
protection of AC electricity
for the outdoor model
F3
4
Communication fault between the IPM and outdoor PCB
F19
6
Power voltage is too high or low
F4
8
Overheat protection for exhaust temperature
F21
10
Frost-removing temperature sensor failure
F6
12
Ambient temperature sensor failure
F25
13
Exhaust temperature sensor failure
E7
15
Communication fault between indoor and outdoor units
F11
18
deviate from the normal for the compressor
Indoor
displaying
panel code
indication
Outdoor
(LED1 flash
times)
fault description
Summary of Contents for HSU12VHG-B
Page 43: ...Domestic Air Conditioner HSU12 HG DB SM System Configuration 40 ...
Page 71: ...68 Domestic air conditioner Removal of procedure 9 1 HSU12 HG DB SM ...
Page 74: ...71 Domestic air conditioner Removal of procedure three two HOOKS HSU12 HG DB SM ...
Page 76: ...73 Domestic Air Conditioner Removal of procedure 9 4 HSU12 HG DB SM ...
Page 77: ...74 Removal of procedure 9 5 HSU12 HG DB SM Domestic Air Conditioner ...
Page 78: ...75 Domestic air conditioner Removal of procedure 9 6 HSU12 HG DB SM ...
Page 79: ...76 Domestic air conditioner Removal of procedure 9 7 HSU12 HG DB SM ...
Page 80: ...Domestic air conditioner 77 Removal of procedure HSU12 HG DB SM ...
Page 81: ...Domestic air conditioner Removal of procedure 78 HSU12 HG DB SM ...
Page 82: ...79 Domestic air conditioner Removal of procedure HSU12 HG DB SM ...
Page 83: ...80 Removal Procedure 9 HSU12 HG DB SM ...
Page 84: ...81 Removal Procedure HSU12 HG DB SM ...
Page 85: ...Removal Procedure 82 4 HSU12 HG DB SM ...
Page 86: ...83 Removal Procedure HSU12 HG DB SM 9 10 ...
Page 87: ...84 Removal Procedure 11 HSU12 HG DB SM ...
Page 88: ...85 Removal Procedure 12 HSU12 HG DB SM ...
Page 89: ...86 Removal Procedure HSU12 HG DB SM ...
Page 90: ...87 Removal Procedure HSU12 HG DB SM 9 13 ...