background image

Trouble shooting

Normal
Performance
inspection

Noise is heard

Phenomenon

Cause or check points

The system 

immediately.

Smells are

generated.

Mist or steam are 

Multiple

check

Poor cooling

When unit is stopped, it won't restart 

elapsed to protect the system.
When the electric plug is pulled out 
and reinserted, the protection circuit 

During unit operation or at stop, 
a swishing or gurgling noise may 

(This noise is generated by

refrigerant flowing in the system.)

During unit operation, a cracking

noise may be heard.This noise is

temperature changes.

Should there be a big noise from

 filter may be too dirty.

This is because the system 
circulates smells from the interior

During COOL or DRY operation, 

This is due to the sudden cooling

Is power plug inserted?
Is there a power failure?
Is fuse blownout?

Is the air filter dirty?

Are there any obstacles before 

Is temperature set correctly?
Are there some doors or 

Is there any direct sunlight
through the window during the 

Are there too much heat sources
or too many people in the room 

In dry mode, fan 
speed can’t be 
changed.

In DRY mode, when room temperature

2

o

C,unit will run

regardless of FAN setting.

during cooling operation?

cooling operation?(Use curtain)

 windows left open?

 inlet and outlet?

Normally it should be cleaned 
every 15 days.

intermittently at LOW speed 

becomes lower than temp.

indoor unit may blow out mist.

of indoor air.

air such as the smell of furniture,

paint, cigarettes.

air flow in unit operation, air 

generated by the casing expanding

or shrinking because of

be heard.At first 2-3 minutes after

unit start, this noise is more noticeable. 

will work for 3 minutes to protect the

air conditioner.

immediately until 3 minutes have

 Cautions

3. If the fuse of indoor unit on PC board is

it with the type of T. 3.15A/ 250V

outdoor

  broken,change it with the type of T.25A/250V

     Do not obstruct or cover the ventilation

conditoner.Do not put fingers

inlet/outlet and swing louver.

     Do not allow children to play with the air conditioner

case should children be allowed to sit on the outdoor unit.

The refrigerating circuit is leak-proo f.

1.Applicable ambient temperature range:

 Specifications

The machine is adaptive in following situation

The power plug and connecting cable

acquired the local 

2. If the power supply cord is damaged, it must be replaced 

manufacturer

qualified

   person.

4. The wiring method should be in line with

   the local wiring

5. After installation, the power plug should

   be easily reached.

6. The waste battery should be disposed

   properly.

7. The appliance is not intended for use

 persons

    without supervision.

8. Young children should be supervised

with

    the appliance.

9. Please employ the proper power plug,

cord.

11.In order to protect the units,please turn

30 seconds

     later, cutting off the power.

10.

Cooling

Indoor

Maximum:D.B/W.B

Maximum:D.B/W.B

D.B

Maximum:D.B

D.B

Minimum:D.B/W.B

Maximum:D.B/W.B

Minimum:D.B/W.B

Outdoor

Indoor

Outdoor

Heating

32

o

C/23

o

C

24

o

C/18

o

C

o

C/-8

o

C

43

o

C/26

o

C

18

o

C

27

o

C

21

o

C/15

o

C

Outdoor

Maximum:D.B/W.B

Minimum:D.B

24

o

C/18

o

C

-15

o

C

(INVERTER)

0

o

C

7

-

Minimum:

Minimum:

grille of the air 

or any other things into the 

.In no

   or its service agent or a similar 

   broken,please

. If the fuse of 

standard.

by young children or

    to ensure that they

    which fit into the 

must have

     off the A/C first, 

Before asking for service, check the following 
first.

blown out.

does not restart

by the 

change

unit is

infirm

do not play

    power supply

attestation.

and at least 

Summary of Contents for HSM24HEK03

Page 1: ...AUTIONS Contents 1 9 10 13 14 ndice PRECAUCIONES COMPONENTES Y FUNCIONES FUNCIONAMIENTO MANTENIMIENTO RESOLUCI N DE PROBLEMAS 1 16 17 20 21 Contenuti AVVERTENZE PARTI E FUNZIONI FUNZIONAMENTO MANUTENZ...

Page 2: ...reference Please be subject to the actual produce purchased the above picture is just from your reference Air Purifying Filter inside Inlet 1 Inlet grille 2 Outlet 3 adjust left and right air flow Ve...

Page 3: ...peration air conditioner will automatically select Cool or Heat operation according to room temperature to AUTO the air conditioner automatically adjusts temperature When FAN is set the fan speed acco...

Page 4: ...hen TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in...

Page 5: ...the system yourself the dismantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the...

Page 6: ...e water out of the cloth before wiping then wipe off the detergent completely Air Filter cleaning Open the inlet grille by pulling it upward Remove the filter Clean the filter Attach the filter Close...

Page 7: ...BITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or...

Page 8: ...3 minutes to protect the air conditioner immediately until 3 minutes have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type...

Page 9: ...O DE SE AL 14 Indicador de TEMPORIZADOR DE APAGADO 15 Indicador de TEMPORIZADOR DE ENCENDIDO 16 Indicador de RELOJ 17 Indicador de la funci n SUE O 18 Bot n ENCENDIDO APAGADO 19 Bot n OSCILACI N 20 B...

Page 10: ...ento de prueba Ajuste de la direcci n del ujo de aire 1 Indicador de estado de env o de aire Aler n vertical Pos 1 Desactivado Pos 2 Pos 3 Pos 4 Oscilaci n autom tica 2 Ajuste del ujo de aire hacia la...

Page 11: ...te y se cancelar el otro modo Funci n de reanudaci n tras fallos en el suministro el ctrico 1 Si es la primera vez que se arranca la unidad el compresor no se pondr en marcha a menos que hayan transcu...

Page 12: ...TEMPORIZADOR DE APAGADO TEMPORIZADOR DE ENCENDIDO APAGADO DESACTIVADO REQUISITOS DE ELIMINACI N Su aparato de aire acondicionado ha sido marcado con este s mbolo el cual indica que los productos de t...

Page 13: ...n agua Escurra el agua del pa o antes de pasarlo sobre la unidad A continuaci n elimine por completo todos los restos de detergente No utilice ninguno de los siguientes productos para limpiar la unida...

Page 14: ...e el cable de la fuente de alimentaci n PROHIBIDO Extreme la precauci n para evitar da ar el cable de la fuente de alimentaci n PROHIBIDO No inserte objetos a trav s de la toma de entrada o salida de...

Page 15: ...emperatura correctamente Existen puertas o ventanas abiertas Penetra la luz solar directamente a trav s de las ventanas durante el funcionamiento en modo de refrigeraci n Utilice cortinas Existen dema...

Page 16: ...Temperatura 13 INVIO DEL SEGNALE 14 Icona Timer spegnimento 15 Icona Timero accensione 16 Icona Orologio 17 Icona Sospensione 18 Tasto Accensione spegnimento 19 Tasto Oscilla 20 Tasto Ora Accensione S...

Page 17: ...a il funzionamento sospensione non disponibile Funzionamento di emergenza e test Regolazione della direzione del usso d aria 1 Visualizzazione dello stato dell aria inviata Aletta verticale Pos 1 vuot...

Page 18: ...poraneamente in base al tempo di operativit che termina prima l unit si spegner automaticamente e l altra modalit verr annullata Funzione di recupero da black out 1 Quando l unit viene avviata per la...

Page 19: ...gnimento VUOTO REQUISITI PER LO SMALTIMENTO Il condizionatore acquistato contrassegnato con questo simbolo che sta ad indicare che le parti elettriche ed elettroniche non devono essere mischiate con i...

Page 20: ...prima di passarlo quindi togliere completamente il detergente Per la pulizia non usare quanto segue Benzina diluenti o soluzioni detergenti possono danneggiare il rivestimento dell unit Acqua calda o...

Page 21: ...i alimentazione DIVIETO Non inserire oggetti nell ingresso o nello scarico dell aria DIVIETO Non avviare o arrestare l unit scollegando il cavo di alimentazione ecc DIVIETO Non dirigere il usso dell a...

Page 22: ...15 giorni La presa e l uscita d aria sono ostruite La temperatura impostata correttamente Ci sono porte o nestre aperte La luce del sole entra direttamente nella stanza mentre in funzione il condizion...

Page 23: ...hage MINUTERIE EN MARCHE 16 Af chage HORLOGE 17 Af chage SOMMEIL 18 Bouton MARCHE ARR T 19 Bouton POSITION 20 Bouton ALIMENTATION HEURE DOUX Utilis pour pour r gler l heure et le minuteur Appuyez sur...

Page 24: ...ATEUR le mode SOMMEIL n est pas disponible Fonction d urgence et test R glage de l orientation du ux d air 1 Af chage de l tat d envoi d air Volet vertical Pos 1 vide Pos 2 Pos 3 Pos 4 Position auto 2...

Page 25: ...temps de fonctionnement se terminera en premier provoquera l arr t de l appareil et l annulation de l autre mode Fonction Reprise apr s panne de courant 1 Si l appareil est d marr pour la premi re fo...

Page 26: ...appareil de climatisation est marqu de ce symbole Ceci signi e que les produits lectriques et lectroniques ne doivent pas tre m l s aux d chets m nagers non tri s Ne pas tenter de d monter le syst me...

Page 27: ...dans de l eau Essorer le chiffon avant de nettoyer puis totalement ter le d tergent Ne pas nettoyer avec les produits suivants essence benzine dliluant ou poudre nettoyer pouvant endommager l enduit d...

Page 28: ...ique INTERDICTION Ne pas ins rer d objets dans l entr e ou la sortie d air INTERDICTION Ne pas d marrer ou arr ter le fonctionnement en d connectant le cordon d alimentation INTERDICTION Ne pas dirige...

Page 29: ...l un obstacle devant l entr e et la sortie d air La temp rature est elle correctement r gl e Des portes ou des fen tres sont elles ouvertes Existe t il un ensoleillement direct venant d une fen tre du...

Reviews: