Trouble shooting

Followings are not problems

Sound  of  water  flowings  are  not
problems.

Sound of cracking is heard.

Smells are generated.

During operation, white fog or steam
comes out of indoor unit.

In  cooling  operation,  unit  switches  to  fan
operation.

Unit will not restart after stop.
Won't start?

No outlet air or fan speed can't be changed in
dry mode.

In heating operation, water or
steam are blown out of indoor
unit.

In heating operation, indoor fan won't stop even
if unit is stopped.

During unit start and operation or at stop, a swishing or
gurgling noise may be heard. This noise is generated by
refrigerant flowing in the system.

During unit operation, a cracking noise may be heard.
This noise is generated by the casing expanding or
shrinking because of temperatuer changes.

This is because the system circulates smells from the
interior air such as the smell of cigarettes or the painting
on the unit.

When unit is running at places like restaurant where dense
edible oil fumeis always exist, this will happen.

To  prevent  frost  from  accumulating  on  indoor  heat
exchanger, unit will switch to fan operation for a while
then resume cooling operation.

Though ON/OFF button is set to
ON, unit won't resume cooling,dry
or heating operation in 3 min after
it is stopped, this is because of 3-
min-delay protection circuit.

Unit will reduce fan speed repeatedly and automatically
if room temp. is too low in dry operation.

T h i s   o c c u r s   w h e n   f r o s t
accumulated on the outdoor unit
is removed.
(during defrosting operation)

After unit stops, indoor fan will go on running until indoor
unit cools down.

Please wait 3 minutes

Summary of Contents for HPU-48HK03

Page 1: ...l before using the air conditioner No 0150509772 B Operation Installation Manual CABINET TYPE AIR CONDITIONER Please keep this manual carefully and safely HPU 42CH03 HPU 48CJ03 HPU 42HH03 HPU 42HI03 H...

Page 2: ...tent Cautions Parts Operation hints Energy saving Maintenance Trouble shooting When problems occur Indoor outdoor unit connection Tools necessary Installation procedures Others 5 6 7 8 9 10 11 12 13 1...

Page 3: ...the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no...

Page 4: ...epairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for the user of the air conditoiner Do not damage any parts of the air conditioner that c...

Page 5: ...is button the unit will enter Auto Run mode according to the room temperature POWER RUN TIMER HEATER ON OFF POWER RUN TIMER HEATER ON OFF HPU 42CH03 HPU 48CJ03 HPU 42HI03 1 2 1 Inlet grill 2 Outlet gr...

Page 6: ...g mode it will be automatically reduced as room temp is approaching temp setting In dry mode fan speed will change automatically 4 Operation hints Cold draft prevention Use objectively Defrosting In h...

Page 7: ...ir filter is clogged It will cause poor cooling and heating efficiency higher power consumption and even problem may occur In cooling operation water will flow out Use Timer effectively You may use Ti...

Page 8: ...t touch it with wet hand Don t wash with hot water or solvent to clean the unit Don t use hot water over 40 C as this may cause damage to air filter Wipe air filter carefully Caution Pull it out from...

Page 9: ...after making sure it is cleaned Dust will enter into unit causing damages or faults if it is running without air filter To protect compressor at start please connect external power supply to the unit...

Page 10: ...erated by the casing expanding or shrinking because of temperatuer changes This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the uni...

Page 11: ...Air conditioner won t start Is power supply switch turned on Power supply switch is not set at ON Are operation controlls adjusted correctly as specified Are horizontal louvers at up position in heat...

Page 12: ...rent leakage For installation in other places use circuit breaker as far as possible Such means for disconnection must be incorporation in the fixed wiring The breaker of the air conditioner should be...

Page 13: ...utdoor unit connection power cable length Approx 1 5m Approx 2m pipe direction Left Rear Right Bottom Over 10cm Over 10cm Over 10cm Over 10cm Over 10cm Over 60cm Over 15cm Over 100cm Take HPU 42CH03 F...

Page 14: ...ia hole core drill 4 Spanner dia 17 27mm 5 Spanner 14 17 27mm 6 Pipe cutter 7 Flaring tool 8 Knife 9 Nipper 10 Gas leakage detector or soap water 11 Measuring tape 12 Reamer 13 Refrigerant oil Followi...

Page 15: ...and will not cause vibration and noise Place where discharged wind and noise doesn t cause a nuisance to the neighbors Place where is less affected by rain or direct sunlight and is sufficiently venti...

Page 16: ...should be decided according to installtion place and piping direction refer to installation drawings Making a wall hole Drill a hole of 70mm dia with a little slope towards outside Install piping hol...

Page 17: ...een the fitting metal and the unit After confirming that the unit has been set up vertically to the floor fix it to the floor by bolt Piping connection Connecting method Apply refrigerant oil at half...

Page 18: ...ping on indoor unit with union of connecting pipe Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape Insert the bound pipi...

Page 19: ...acuumizing 1 Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage 2 Under the condition of the complete close of the indoor and outdoor valve center both liquid and g...

Page 20: ...l it out from front Loose terminal screw and insert cable end fully into terminal block then tighten it Pull the cable gently to make sure it is tight Replace cover after wiring The power cable should...

Page 21: ...outdoor securely fixed Is draminage securely carried out Is earth line grounding securely connected Is power supply voltage abided by the code Is there any noise Is control display normal Is cooling o...

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: