- If a power cable is damaged, it shall be replaced by qualified professionals to avoid risks.
- In the case of places and walls where water may be splashed to, installation height of a power
socket shall not be less than 1.8 m, and it shall be ensured that water would not be splashed on
these places. The socket shall be installed out of children’s reach.
- The phase line, zero line and ground line inside a power socket used in your home shall be wired
correctly without any wrong positioning or false connection, and internal short circuit shall be
avoided. Wrong wiring may cause fire accidents.
h.
Off-peak power signal wire connection(HP200M2/HP250M2)
Connection with boiler back up(only for HP250CM2)
Power cable (3*1.5mm
2
)
Off-peak power signal wire
(2*0.75mm
2
,Black wire)
16A
Auto
1
0
123kwh
1
0
16A
B
oil
er
Boiler signal wire
(2*0.75mm
2
White wire)
Power cable (3*1.5mm
2
)
Off-peak power signal wire
(2*0.75mm
2
,Black wire)
Auto
1
0
123kwh
1
0
Boiler sensor