16
- If the mains pressure exceeds 80% of safety valve, a pressure reducer must be installed upstream
of the appliance.
.
Do not connect the domestic hot water connection directly to copper pipes in order to prevent
galvanic couples in iron/copper (risk of corrosion). It is compulsory to fit the domestic hot water
connection with a dielectricconnection (not supplied).
- Pressure relief valve, thermostatic valve, stop valve, check valve, T&P valve and French
combination valve are not included in the accessories, please select proper fittings in
local market;
- Valves with NF/CE certification are recommended