background image

11

 

2. Laundry loading

   Open the door and place the

laundry into the drum of the dryer 

.

To save energy and achieve a better 

drying result, please spin the laundry as

dry as possible. Place the laundry evenly

into the drum after shaking them loose. 

  Note: Do not put excess laundry into 

the dryer to avoid damage to the dryer

and laundry.

3. Setting drying program

Turn the program knob to set an optimal drying program according to the 

laundry type and the drying result required.

4.

Selecting additional functions

    According to you desire, select the additional function:

- Start Delay,- Deliacate,- Anti-crease,- Signal Off.

5. Program operation

    After a program is set, gently touch the Start/Pause button to start the 

program

6. Program completion

    Before the drying program ends, the dryer will enter the cold air cycle.

After the program is complete, the display screen will display "End." Open

the door to remove the laundry.If the laundry is not removed  after the drying

program is complete,the dryer will start  the anti-crease protection cycle 

automatically.In the anti-crease protection cycle, the dryer's drum will run at 

a set interval to keep your laundry loose.

.

  

7. Turning off the dryer

Press the power keystoke to cut off the power supply and turn off the dryer 

at  the wall socket.

1.Turning on power

Insert the power plug into an appropriate wall socket and turn on the power.

.

Operating power supply: (220-240)V/50Hz.

       Overalls

(cotton appr 950g)

Blended fabric

 clothes

(appr 800g)

    

          T-shirt

     (appr 300g)

 

Jackets (cotton

appr 800g)

 

 

Woolen blankets

(appr 3000g)

 

 

Single bed sheets

(cotton appr 800g)

 

 

 

           Socks

(blended fabrics

appr 50g)

 

 

Underwear

( appr 70g)

 ●

 Jeans

800 )

Pajamas

(appr 200g)

 

 

 

     Shirts

(appr 300g)

 

 

Reference weight of fabrics for drying

Drying Methods

g

appr 

 

10

Programming Guide

Program

Degree of drying 

One piece

Cotton fabrics, sheets, coats

Ordinary synthetic fabrics

 Max. load

Damp

 Extra dry

 Type of Laundry

 Refresh/Airing

Ordinary cotton fabrics 

 7 kg

Heavy cotton fabrics, sheets,

gowns.

 Ready to wear

 7 kg

 Ready to iron

 7 kg

 7 kg

Ordinary cotton fabrics 

SYNTHETIC

 Ready to wear

 Ready to iron

 3 kg

3 kg

Ordinary synthetic fabrics

TIMER

 Timer 20 min

 Timer 40 min

 Timer 60 min

 7 kg

 7 kg

 7 kg

Heavy fabrics, needing 

further drying.

SPECIAL PROGRAMS

 7 kg

/

* Programme setting for testing in accordance with EN 61121.

/

 0.5 kg

*

Humide

20 min

Sec

Prêt à 

ranger

Prêt à 

repasser

Coup de 

    frais

Délicat

Prêt à 

ranger

Prêt à 

repasser

60 min

40 min

COTTON

Summary of Contents for HDY-D70-F

Page 1: ...er Program selector Container handle Name of Parts Door Plinth SAVE THESE INSTRUCTIONS Programming guide 10 Important Safety Instructions 2 3 Name of Parts 1 This diagram may be slightly different from the layout of the machine you have just purchased due to techincal improvements Read all instructions before using dryer Dryers are provided with operating care and in stallations instructions Warni...

Page 2: ...o catch fire 11 Clean lint screen before or after each load 12 This dryer must be properly installed in accordance with the installation instructions before it is used 13 To prevent shock hazard and assure stability during operation the dryer must be installed and electrically grounded by a qualified service person in accordance with local codes 14 Always disconnect dryer from electrical supply be...

Page 3: ...er the ambient temperature shall not be lower than 10 nor higher than 35 Change the door opening direction If the direction of the dryer s door is not suitable to the location its opening direction may be changed The procedure is as follows 1 Unscrew the 4 hinge screws holding the door onto the machine and remove the door 2 Unscrew the door catch 6 and prise out the catch cover on the opposite sid...

Page 4: ...on Before use clean any deposits from inside the drum of the dryer with a wet towel Clean debris on the filter screen to increase the drying efficiency Warning Do not dry wool silk down and other delicate fabrics to avoid damage to fabrics Load to dry Make sure that the laundry you are going to dry is suitable for drying in a dryer You will find information on this on the laundry labels The follow...

Page 5: ...onds once again and the child lock will release When the program is end or the power off during the program the child lock will release H LED screen The screen displays the remaining time for a program the delay time and other related information Note The remaining time to start a program is the default time for the program During operation with variation of factors such as the moisture content Th...

Page 6: ... at a set interval to keep your laundry loose 7 Turning off the dryer Press the power keystoke to cut off the power supply and turn off the dryer at the wall socket 1 Turning on power Insert the power plug into an appropriate wall socket and turn on the power Operating power supply 220 240 V 50Hz Overalls cotton appr 950g Blended fabric clothes appr 800g T shirt appr 300g Jackets cotton appr 800g ...

Page 7: ... emptied and the dryer will stop It will not restart until the box is emptied 4 Cleaning the condenser The condenser must be cleaned monthly Switch off the power supply before cleaning Hold the protrusions on both sides of the lower deco panel and open it 13 Using a coin or other tool push the slides on the cover to the position as shown in the figure and then remove the cover Turn the condenser s...

Page 8: ...me display is halted or the remaining time displayed is skipping The remaining time will be adjusted and corrected continuously and automatically based on the following factors Type of laundry Loaded amount The degree of spinning dry of laundry Ambient temperature The automatic adjustment is a normal operation 15 E2 E3 E5 E6 Prompt and Alarm Information In case of an improper operation or trouble ...

Page 9: ...ated load kg Type Item Power supply Maximum operating current A Maximum power W Drying program LHDY D70 F 220 240 V 50Hz 12 11 2800 Dimensions H D W mm 855 620 595 17 16 FA Electromagnetic interference inhibitor R1 Heating1 R2 Heating2 T1 Thermal cut out T2 Thermostat PS Drainage pump M Motor NTC Temperature senso H Humidity sensor K2 Level switch K1 Door switch PCB1 PCB2 Printed circuit board PCB...

Reviews: