The flexible tube shall be fitted in such a way that
it cannot come into contact with a moveable
part of the housing unit (e.g. a drawer) and does
not pass through any space where it may
become crushed/ kinked or damaged in any
way.
C: 1/2 Female Gas Adaptor Conical-Cylindirical
or Cylindirical-Cylindirical
For some models a conic link is furnished to
outfit for the installation in the countries where
this type of link is obligatory; in picture 8 it is
pointed out how to recognize the different
types of links (CY = cylindrical, CO = conic). In
every case the cylindrical part of the link has to
be connected to the hob.
To prevent any potential damage to the hob
please carry out the installation following this
sequence (Figure 6*):
A: 1/2 Male Adaptor Cylindirical
B: 1/2 Seal
2. Tighten the joints with the spanner, remembering
to twist the pipes into position.
3. Attach fitting C to mains gas supply using rigid
copper pipe or flexible steel pipe.
When connecting the hob to the gas supply via
use offlexible hoses please ensure that the
maximum distance covered by the hose does
not exceed 2 metres.
1. As illustrated, assemble parts in sequence:
table)
suitable for the gas to be used (see gas type
• Unscrew the injector and replace it with one
To adapt the Hob for use with different types of
gas, carry out the following instructions:
IMPORTANT: carry out a final check for leaks on
the pipe connections using a soapy solution.
Warning: If gas can be smelt in the vicinity of this
appliance turn off the gas supply to the
appliance and call the engineer directly. Do not
search for a leak with a naked flame.
• Remove the grids and burners
• Insert on hexagonal spanner (7 mm) into the
ADAPTING THE HOB TO DIFFERENT TYPE
OF GAS
NEVER USE A FLAME. Also, make sure that the
flexible pipe cannot come into contact with a
moving part of the cabinet (eg.adrawer) and that
it is not situated where it could be damaged.
burner support (Figure 7*)
When you have carried out the new gas
regulation, replace the old gas rating plate on your
appliance with one (supplied with hob) suitable for
the type of gas for which it has been regulated.
REGULATING THE MINIMUM FLAME
Using a small «Terminal» type screwdriver the
regulating screw can be adjusted as in Figure 9*.
Turning the screw clockwise reduces the gas
flow, whilst turning it anticlockwise increases
the flow – Use this adjustment to obtain a flame
of approximately 3 to 4 mm in length and then
replace the control knob.
After lighting the burners, turn the control knob
to the minimum setting and then remove the
knob (this can easily be removed by applying
gentle pressure).
When the gas supply available is LPG - the
screw to set the idle flame must be turned
(clockwise) to the end stop.
*See “Technical information” section at the end of this manual.