Haier GV270REMB User Manual Download Page 8

Operations

Operation instructions   Troubleshooting  Packing list

Troubleshooting

16

22

30

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

1              

Packing list

1)Before using water, the manual valve, mixing 
    valve (hot water) and mixing valve (cold  
    water) should be closed.
2)To fill water, 

3)

,when water flows 

    from the overflow pipe, it indicates the water
    tank is full. Close the manual valve to finish
    filling  water.
4)To use water, open the mixing valve (hot 
   water) and the water comes from the 
   shower nozzle. If the water is too hot, open 
   the mixing value (cold water) to adjust the 
   water temperature. 
5)After use of water, make sure the manual 
   valve and mixing valves are closed.

use automatic function on the 

    controller,or open the manual valve.

When using manual valve

Phenomena

No water supply

No water from  
the overflow 
pipe

The temperature 
is not high  
enough

Possible causes

The tank is  empty

The pipeline or the connector falls off or is blocked
In the winter, water  in the feeding/outgoing  pipe 
may become frozen
The vacuum tube  is damaged

Tap water supply stopped or  low water pressure

Pipeline or connector  may become broken
In the winter, water  in the feeding/outgoing  pipe  

May become frozen

In bad weather or winter when the sun is relatively 
low, the sunlight  time is short, atmosphere quality is 
poor, and sunshine  radiation energy is insufficient

The valve for  water supply is  loose or damaged

The vacuum tube  cannot effectively collect heat 

due to a  blockage in front  of it
Dust on the  tube

Solutions

Add water according  to the tank

Start the accompanying  heating strap 
or wait for  natural ice-out.

Replace the tube

Wait for normal water supply

Repair or replace  the pipeline or  connector

Start the accompanying  heating strap 

or wait for  natural ice-out.

Use auxiliary electric  heating as an  
option

Tighten or replace the valve
Remove the blockage  or change the  

location for installatio

Clean the tube surface

Main parts

Quantity

Water tank 
package

Water tank (PC)

Sensor (PC)

Manual (Copy)

Tank support (PC)

Glass vacuum tube (PC)

Frame (set)

Controller (set)

Maintain the pipeline or remove the blockage

GV150REMB

GV200REMB GV270REMB

0040503720

  Mixing valve (cold  water)

E

le

c

tr

ic

 h

e

a

tin

g

 w

ir

e

S

e

n

s

o

r  

w

ir

e

Inlet/outlet 
pipe

  Mixing valve

   (hot water)

Solenoid valve

Solenoid valve wire

Non-return

valve

Manual valve

plug

Outdoor

Tap water

Air supply hole

controller

Indoor

Electric
heating
tube

Accompanying
heating
strap

Over flow port

S

e

n

s

o

r

Summary of Contents for GV270REMB

Page 1: ...al for future reference Table of Contents 1 2 2 2 6 6 7 7 User Manual Haier Solar Water Heater Models GV150REMB GV200REMB GV270REMB Safety cautions Product features Technical parameters Installation instructions Operation instructions Troubleshooting Packing list ...

Page 2: ...tely it shall be covered The water heater is equipped with a special venting pipe and overflow pipe To ensure normal operation never refit or plug their outlets Otherwise the water tank will shrink Water shall be fed in early morning or at night when the sunlight is insufficient The water feeding after sunlight exposure of the glass vacuum tube will cause an explosion of the pipe The temperature o...

Page 3: ...ightening protected area of a building in locations prone to lightning strikes 2 The orientation of the water heater to be installed 3 There must be no shielding object in front of the installation location of the water heater If an object exists the space between the heater and the objective shall be more than L 10 south by east and 15 south by west in the Northern Hemisphere 10 north by west and...

Page 4: ...mensions unit mm 1600 2597 1957 1320 2435 1775 1725 1725 1725 1490 1490 1490 Installation instructions GV150REMB GV270REMB GV200REMB Diagram of appearance structure Water outlet Electric heating tube Tank support Scissors truss support Front post Back post Scissors truss support Cross member Foot Support foot Tail joist The diagram subject to GV150REMB is for reference only ...

Page 5: ... and use inner ratchet teeth to directly connect tothe PEX pipe Before installation check that the gasket ring of the water inlet and outlet pipe is intact Notice 1 Rip off the protection film after installationto avoid the destroy of the tank and please do not use the sharp tool 2 Leave nuts loose since some adjustment may be necessary after fitting tubes 3 When assembling the water tank keep the...

Page 6: ...tall one tube on each end of the heater tank respectively first so that the heater tank and frame are positioned as a whole Seal ring Air seal ring Vacuum tube A Tail base Tail support B Tail base Vacuum tube Tail support C Air seal ring Sealing location D Notice 1 Check whether the seal rings in tank holes are sufficiently installed and whether the sealing location is clean and free from foreign ...

Page 7: ... installation project should be confirmed by our professional service personnel when installing several sets of the series of the products Connection of water supply pipes when the solar water heater coexists with other water heaters Please install another non return valve on the cold and hot water pipes respectively if the solar heater coexists with other water heaters so as to avoid accidents ca...

Page 8: ...the winter water in the feeding outgoing pipe May become frozen In bad weather or winter when the sun is relatively low the sunlight time is short atmosphere quality is poor and sunshine radiation energy is insufficient The valve for water supply is loose or damaged The vacuum tube cannot effectively collect heat due to a blockage in front of it Dust on the tube Solutions Add water according to th...

Reviews: