Safety cautions

 (please read the cautions before use)

 

Description of 

symbols 

Behaviors that are 
prohibited 

Prohibit 

Directions that must 
be followed. 

Warning

Directions that must 
be noted. 

Caution

Personnel other than professional 

maintenance staff are prohibited from 

repairing, maintenance, dismantling or 

altering the water heater without 

authorization. 

Prohibit 

Warning 

Warning! Improper operation of the following may lead to personal 

injury or even death!

Caution! Improper operation of the following may lead to personal injury or even death or property loss!

Prohibit

Prohibit 

Caution 

Please do not use the hot water in the 

heater for drinking or similar purposes. 

 

To guarantee effectiveness, do not feed 

water to the heater several times within 

one day in case of insufficient sunlight 

exposure. 

 

The source of the energy for the water 

heater is solar energy, so it may be 

incapable of being used normally under 

cloudy, rainy and snowy weather 

conditions due to the failure to reach 

desired water temperature because of 

insufficient sunlight exposure. 

Caution 

Warning

Warning

Warning

The glass vacuum tube shall not be 

exposed for a long period without water 

inside after installation to avoid the 

shortening of the service life. If it cannot be 

used immediately, it shall be covered. 

 

Make sure of the smooth ventilation of the 

air pipe. It is strictly prohibited to block the 

outlet of the air pipe to avoid the collapse of 

the water tank under suction. 

 

Water shall be fed in early morning or at 

night when the sunlight is insufficient. The 

water feeding after sunlight exposure of the 

glass vacuum tube will cause an explosion 

of the pipe. 

-Suggestions- 

The water heater is non-pressurized, gravity-fed water heater relying on the height 
difference of the water tank and point of use to supply hot water with the outgoing water 
pressure in direct proportion to the height. An additional pressurizer may be required. 

 

Do not touch glass vacuum tube, pipes and 

valves for supplying hot water during use to 

avoid being burned. 

 

 

Please feel the water temperature by hand 

before use to make sure of proper water 

temperature while in use 

1

Summary of Contents for GV150REMB

Page 1: ...thout electric auxiliary heating function Please read through the manual before use Please keep the manual for future reference Table of Contents Safety cautions Product features Technical parameters Installation instructions Operation instructions Troubleshooting Packing list 1 2 2 2 6 7 7 7 ...

Page 2: ...the failure to reach desired water temperature because of insufficient sunlight exposure Caution Warning Warning Warning The glass vacuum tube shall not be exposed for a long period without water inside after installation to avoid the shortening of the service life If it cannot be used immediately it shall be covered Make sure of the smooth ventilation of the air pipe It is strictly prohibited to ...

Page 3: ... the permitted error limit of other parameters is 10 Installation instructions Selection of installation location 1 The water heater shall be installed within the lightening protected area of a building in locations prone to lightning strikes 2 The orientation of the water heater to be installed 10 south by east and 15 south by west 3 There must be no shielding object in front of the installation ...

Page 4: ...unit mm Installation dimensions unit mm Models A H D B GV110RNMB 1190 1000 GV150REMB 1600 1320 GV200REMB 1990 1800 GV270REMB 2630 1725 2440 1490 Installation instructions Diagram of appearance structure Water outlet Electric heating tube Tank support Scissors truss support Front post Back post Scissors truss support Cross member Foot Tail joist 3 ...

Page 5: ...d nuts 3 Remove the sensor wound around the tank and install it onto the sensor hole on the tank Non welding pipe ends 1 Pipe fittings are connected with the pipe by a non welding method 2 During installation use a wrench to fasten the tank pipe end Do not rotate the tank pipe ends and do not apply any force along the axial direction of the fittings to avoid damage of the seal ring 3 When installi...

Page 6: ...e open end of the tube with a clearance of around 10cm from pipe end Make the pipe end wet before insertion for easy assembly Installation of electric heater and Operation instructions Wiring of electric heater 1 Unscrew the four screws on the terminal box cap take out the cap and remove the bonding clamps 2 Put the power cables of 3X1 0mm2 across the seal ring of the bushing Connect wires accordi...

Page 7: ...return valve shall be installed at the joint of the water upward downward pipes and the tap water 5 The installation project should be confirmed by our professional service personnel when installing several sets of the series of the products Connection of water supply pipes when the solar water heater coexists with other water heaters Installation instructions Air pipe Water feedin g pipe Electric...

Page 8: ...maged Replace the tube No water supply Suspended tap water supply or low water pressure Wait for normal water supply The valve for water supply is loose or damaged Tighten or replace the valve The vacuum tube cannot effectively collect heat due to a blockage in front of it Remove the blockage or change the location for installation The temperature is not high enough Dust on the tube Clean the tube...