Page 25
31-5000727 Rev. 0
Maximum Allowable Intake or Exhaust Vent Length in Feet
Standard Termination at Elevation 0 - 4500 ft
Number of 90°
Elbows Used
1-1/2" Pipe
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
070
090
110
070
090
110
070
090
110
070
090
110
1
15
n/a
n/a
51
29
9
100
78
43
122
103
103
2
10
46
24
n/a
95
73
38
117
98
98
3
n/a
41
19
90
68
33
112
93
93
4
36
14
85
63
28
107
88
88
5
31
9
80
58
23
102
83
83
6
26
n/a
75
53
18
97
78
78
7
21
70
48
13
92
73
73
8
16
65
43
8
87
68
68
9
11
60
38
n/a
82
63
63
10
6
55
33
77
58
58
Standard Termination Elevation 4500 - 10,000 ft
Number of 90°
Elbows Used
1-1/2" Pipe
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
070
090
110
070
090
110
070
090
110
070
090
110
1
15
n/a
n/a
51
29
n/a
100
78
43
122
103
103
2
10
46
24
95
73
38
117
98
98
3
n/a
41
19
90
68
33
112
93
93
4
36
14
85
63
28
107
88
88
5
31
9
80
58
23
102
83
83
6
26
n/a
75
53
18
97
78
78
7
21
70
48
13
92
73
73
8
16
65
43
8
87
68
68
9
11
60
38
n/a
82
63
63
10
n/a
55
33
77
58
58
*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
Table 10A.
Summary of Contents for GE NF96DV