Fan Cycle - Heat Pump Mode
Temp. S0.9°F
Temperature
COMPRESSOR AND
OUTDOOR FAN
INDOOR FAN
ON
ON
ON
ON
6
sec
3
sec
AZ6500 series ONLY.
The indoor fan is turned on 3 seconds before the compressor and outdoor fan is turned ON. The
outdoor fan and the compressor are turned ON at the same time. The indoor fan is then turned OFF 6
seconds after the compressor and outdoor fan are turned OFF.
FAN CYCLE: HEAT PUMP MODE