English
English
11
The following are specific requirements for proper
and safe electrical installation of your dryer. Failure to
follow these instructions can create
electrical shock and/or fire hazard.
WARNING
Gas dryers are equipped with a factory installed three-prong 15 Amps ~120 Volts
(grounding) plug for your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
GAS CONNECTION
NOTE: DO NOT connect the dryer to L.P. gas service without converting the
gas valve. An L.P. Conversion Kit must be installed by a qualified
gas technician.
1. Remove the shipping cap from gas pipe at the rear of the dryer.
2. Connect a 1/2 inch (1.27cm) I.D. semi-rigid or approved pipe from gas supply line to
the 3/8 inch (0.96cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27cm to 0.96cm) reducer for a connection. Apply an approved thread sealer
that is resistant to the corrosive action of liquified gases on all pipe connections.
3. Open the shutoff valve in the gas supply line.
4. Test all connections by brushing on a soapy water solution.
NEVER TEST FOR GAS
LEAKS WITH AN OPEN FLAME.
5. Connect the exhaust duct to the outside exhaust system. Use duct tape to seal
all joints.
6. With the dryer in its final position, adjust one or more of the legs until the dryer is
resting solid on all four legs. Place a level on top of the dryer.
THE DRYER MUST BE
LEVEL AND RESTING SOLID ON ALL FOUR LEGS.
7. Plug the power cord into a grounded outlet.
NOTE:
check to ensure power is
OFF
at
circuit breaker/fuse box before plugging the power cord into the outlet.
8. Turn on the power at the circuit breaker/fuse box.
WARNING
ADVERTENCIA
ADVERTENCIA
ADVERTISSMENT
PRECAUCIÓN
PRECAUCIÓN
PRECAUCIÓN
ATTENTION
CAUTION
CAUTION
Before operating the dryer, make sure the dryer area is clean and free
from combustible materials, gasoline, and other flammable vapors. Also
see that nothing (such as boxes, clothing, etc.) obstructs the flow of
combustion and ventilation air through the louvered panel located on the
rear of the dryer.
9. Run the dryer through a cycle check for proper operation.
NOTE:
On gas dryers, before the burner will light, it is necessary for the gas line to be
bled of air. If the burner does not light within 45 seconds the first time the dryer is
turned on, the safety switch will shut the burner off. If this happens, turn the dryer
to “OFF” and wait 5 minutes before making another attempt to light.
NOTE:
Follow instructons supplied with kit.
ELECTRICAL INSTALLATION