background image

Installation methods

8

Precautions during use

To avoid damage, never turn on the power before the inner tank is fully filled with water.
To avoid scalding, adjust the water temperature to an appropriate degree before use.
Water over 50

 can result in scalding.

The relief valve should be checked once every two weeks during use. The method: turn 
the small handle of the relief valve. It is normal if there is water flowing from it. If not, 
please contact local after-sales service center.
The product is a water heater of enclosed type. It can supply hot water to several 
locations such as bathroom (bathtub, hand wash basin, shower nozzle) and kitchen.
If the water heater is not to be used for an extended period or if it is to be repaired, please 
turn off the inlet valve and turn on the relief valve to relieve pressure. Then, open the 
water outlet and blowdown port to drain the water in the inner tank. Before reusing, to 
avoid injury or accidents, it is recommended to turn on the hot water valve before turning 
on the power of the water heater. In this way you can discharge air in the pipeline. At this 
time, please do not smoke or light other open flames near the open valve. Meanwhile, 
carefully check that all the components of the water heater are in good condition. It can 
be put into use after all of these are confirmed. Note: the other end of the drain hose may 
not be higher than the pressure relief hole of the relief valve. The drain hose should be 
inserted into the floor drain or other places to facilitate draining.
Please ask a service person to conduct safety examinations regularly. Remove the scale 
on the heating element in time. Check the consumption of the magnesium anode rod and 
replace it in a timely manner if it is too seriously worn.

Relief valve

(Fig. )

3

Connection and use of the check valve:
Connect the check valve with G1/2  connection screw according to the arrow on it.

Mount the relief valve on the water heater with position as 
shown in Fig. 

 Fit the double nipple in the relief hole of the 

relief valve and then screw one end of the drain hose onto 
the double nipple (as shown on Fig.  ). When the water 
heater is powered on, a small amount of water may drip out 
of the drain hose. This is a normal phenomenon caused by 
expansion of water inside the water heater. The relief hole 
must be kept unblocked.
The drain hose can be cut short or extended as necessary. 
Connect the other end of the drain hose to the sewage drain 
to avoid polluting by splashing. The drain hose connecting 
the relief valve should be installed in a continuous downward 
direction and in a frost-free environment. 
Be sure to check and confirm that the tank is fully filled with 
water, that there is no leakage from any joints, and that the 
power supply complies with the requirements before 
switching on the power.

2.

3

5

Instruction 
   manual 
   (Copy)

Check 

valve

(Pc)

Pipe fitting

                  

     

Pc

Components

Quantity

Model

Electric 

water heater

(Set)

Relief valve / 

drain hose

(Set)

1

1

Special hints

Technical parameters

Be sure to disconnect the power supply before performing any maintenance or repair 
work on it. Only professionals should be allowed to adjust or repair the water

Make sure the water heater is fully filled with water before turning on the power. 
Otherwise malfunction of the heating element may occur. Please make sure the power 
socket complies with applicable national standards and is reliably grounded. Never use 
the water heater without reliable earthing.

The water heater is fitted with a relief valve. To ensure safety, please do not change its 
installation location and never block its outlet.

When the ambient temperature is under 0

, the piping may be damaged due to freezing 

of water in it and cause the water heater to malfunction. So you shall drain the water in 
the tank to avoid freezing. If the water heater is not to be used for a period of over 1 
month, 

If the electrical water heater is seriously soaked with water, it must be examined and 
repaired by a technician authorized by the manufacturer before it is put into use again.

Scale can be formed in the water tank after long periods of use. Besides, water quality 
may change due to ageing of the water pipe. After you wash rice or vegetables with 
water from the water heater, please rinse them with clean tap water.

Do not place flammables such as gasoline near the water heater to avoid fire or other 
accidents.

please unplug the power cord and drain the water tank.

F M

Rated voltage: 220V , 50Hz                    Dimensions: (See Fig. 1)
Power: 2500W                                             Weight/volume: (See Fig. 1)
Rated pressure: 0.7MPa                            Rated temperature: 60
Waterproof grade: IPX4                             Pressure of the tap water: not less than 0.05MPa

Packing list

Special hints

Installation methods  

Packing list

 Technical parameters

 Precautions during use

1
2

3

4

5

6

Summary of Contents for FCD-JLD245

Page 1: ...before usage Retain it for future reference FCD JTLD200 FCD JTLD245 Rev 01 Specific Number 0040501317 Qingdao Economic and Technological Development District Haier Water Heater Co Ltd Haier Garden Qianwangang Road Economic Development Zone Qingdao P R China Group Website http www haier com ...

Page 2: ... 5 10 11 7 8 Precautions during installation 7 Using methods 9 Precautions during use 8 Safety precautions Setting environment Special hints Using instructions Cleaning and maintenance Technical parameters Dimension diagram 5 6 Technical data Appearance and components 6 See to thephysical product forthe appearance coloror pattern ...

Page 3: ...ation layer 5 Convenient operation 60 fixed temperature heating means it will stop heating automatically when the water temperature reaches 60 6 Multiple uses Enclosed structure with several outlets can supply hot water to several places like the washroom kitchen etc the hot water from it is not drinkable It is suitable for residential houses enterprises and service trades like beauty parlors or h...

Page 4: ...tions may cause personal injury or even death This symbol indicates instructions you must observe Neglecting these instructions may cause personalinjury or damageto your houseor property 11 FAQ FAQ Phenomenon Please check Solutions No water outlet Cold water outlet only If the water supply system stops supplying water or the water pressure is too low If the water outlet is blocked If the hot water...

Page 5: ...ater working efficiently the heating elements and the inner tank should be cleaned once every three years Take care not to damage the protection coating outside the heating element and inside the inner tank The magnesium anode rod should be replaced periodically according to local water quality and the using habits To clean the inner tank Blowdown procedure disconnect the power supply turn off the...

Page 6: ...s reducing temperature by relieving pressure as the temperature is too high Please call the after sales service center in this case Please keep away from the drain hose during use to avoid scalding 99 9 Using method In initial use after installation it must be fully filled with water before turning on the power In first use as the inner tank is empty you must turn on the tap and one of the water o...

Page 7: ...he water heater The relief hole must be kept unblocked The drain hose can be cut short or extended as necessary Connect the other end of the drain hose to the sewage drain to avoid polluting by splashing The drain hose connecting the relief valve should be installed in a continuous downward direction and in a frost free environment Be sure to check and confirm that the tank is fully filled with wa...

Page 8: ... a heat preservation layer to reduce heat loss In selecting the installation location of the water heater convenient usage and repairing should be considered Besides it must be installed in a place with a sewer so that it will not cause damage to facilities nearby or downstairs when the water tank and or pipes leak Do not confuse the water inlet pipe and outlet pipe The relief valve shall be insta...

Reviews: