background image

Behind the interior walls, there are many refrigeration tubes. Do not use a knife, an ice pick, or a 

screwdriver to cut ice and frost. This may damage not only the liner but also the refrigeration tubes.
If the freezer is not in use for a long time, please turn off the power and switch off the backup 

battery. The power cord should be unplugged.

Two access ports are installed in the back wall of the unit which can be used as the through hole 

for the thermocouple wires during testing and validation. After all test wires are let through the 

access port, make sure that the gap in the port is sealed properly with insulation materials. 

Otherwise, the unit temperature may not come down to the desired temperature. The port ring in 

the outer wall can also accumulate frost and ice

When the unit operates normally, the unit frame at the front near the door may be slightly warm. 

This phenomenon is normal because hot tubing is embedded there to prevent condensation from 

forming on the frame.

The temperature display indicates the temperature where the temperature sensor is mounted 

inside the unit chamber, which may vary from the temperature at the center of the freezer, but it 

will gradually reach the actual temperature of the freezer over time.

After the freezer runs for some time, a layer of frost usually forms on the interior liner and inner 

doors. When this layer of frost get too thick, it can negatively impact the refrigeration performance 

of the unit. Energy consumption can increase. If the thickness reaches about 5 mm, please use 

the supplied scraper to remove the frost.

Before removing the frost, temporarily transfer the stored samples to another freezer. This is so 

that the temperature does not rise in the unit and damage the samples

Usage Precautions

Before samples are loaded into the unit, make sure the unit temperature has reached the set point 

then load the samples into the freezer in batches. Each batch should not exceed 1/3 0f the unit 

capacity so that the temperature does not rise while samples are being loaded.

When cleaning the unit, mild or neutral detergent solution should be used. Never use a hard wire 

brush, acid, gasoline, detergent powder, polishing powder, or hot water to dean the freezer as 

these tools and materials can damage the paint coating and plastic components. Particularly, 

never use gasoline or a solution with volatile chemicals to clean plastic or rubber parts.

Defrost the interior

Frost and ice can form in between the door gasket and frame to form an air gap, which can 
decrease the refrigeration effect of the unit. Please use the provided plastic scraper to defrost the 
interior doors.
The following steps are how to defrost:
1. Turn off any backup refrigeration system if there is one.
2. Remove the samples from the unit that needs to be defrosted. Move them to another unit or a 
container for temporary storage.
3. Turn off the power supply.
4. Open the outer door and inner doors to let the unit thaw for a period of time.
5. Use a dry doth to soak up and remove any water on the floor of the unit
6. After defrosting the unit and cleaning up the water, restart the unit.
7. Load the samples back into the unit after it reaches the set temperature.
8. Turn on the backup refrigeration system if there is one.

Do not use any sharp tools such as knives or screwdrivers to defrost.

Battery maintenance

When the control panel shows an alarm signal for “Low Battery ”, please make sure the battery 
switch is turned on, and the battery will be charged. After about one week of charging, please 
recheck the battery capacity. If normal, the battery should be in full capacity. However, if the 
capacity is still low. please change the battery.
The battery that supports the power outage alarm is a consumable item. The life expectancy for 
the battery is 2 to 3 years. If the battery is more than 3 years old, the battery should be replaced 
because the alarm function may not work properly. To do so, please contact an Haier Equipment 
and Instrument Service Center.

Disposal of the freezer

If the unit is to be stored unused in an unsupervised area for an extended 
period , ensure that children do not have access and that doors are locked 
completely with a key.
The disposal of the unit should be accomplished by appropriate personnel . 
Remove doors to prevent accidents such as suffocation .

21

8

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection 
facilities.Contact you local government for information regarding the collection systems available. If 
electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the 
groundwater and get into the food chain, damaging your health and well-being.

Meaning of crossed –out wheeled dustbin:

Summary of Contents for DW-86L578S

Page 1: ... 再分批次放入物品 解锁 温度设定操作 按 或 键 显示板LED箱内温度显示区显示 00 按 调节至 06 默认值 可调 按住 键 5秒钟 解锁显示板 显示板锁定指示灯灭 再按一下 键 进入温度设定模式 在解锁状态下按下 设置 键 分别选择 箱内温度设定 高温报警设定 低温报警设定 相应指示灯亮了以后 按 或 键调整所需温度 修改完毕后 按 键保存箱内温度设定值 若20秒无按键 箱内温度设定值不保存 功能锁定后返回显示箱内温度 注意 其他内容请详见说明书 海尔生物医疗 智护生命科学 首次安装或搬动保存箱后 请顺时针旋转水平支脚使其支撑地面 确保保存箱不移动 安装固定 到位后需要静置24小时后再通电使用 为保证空气流通散热 保存箱四周至少保留30cm的间隙 保存箱使用环境温度为10 32 最佳环境温度为18 25 必要时应使用空调系统 湿度应低 于80 RH 环温32 时 湿度应低于57 R...

Page 2: ...选择 箱内温度设定 高温报警设定 低温报警设定 相应指示灯亮了以后 按 或 键调整所需温度 修改完毕后 按 键保存箱内温度设定值 若20秒无按键 箱内温度设定值不保存 功能锁定后返回显示箱内温度 注意 其他内容请详见说明书 海尔生物医疗 智护生命科学 首次安装或搬动保存箱后 请顺时针旋转水平支脚使其支撑地面 确保保存箱不移动 安装固定 到位后需要静置24小时后再通电使用 为保证空气流通散热 保存箱四周至少保留30cm的间隙 保存箱使用环境温度为10 32 最佳环境温度为18 25 必要时应使用空调系统 湿度应低 于80 RH 环温32 时 湿度应低于57 RH 每台保存箱应该独立使用一个插座 且电源插座承受电流应大于16A 并可靠接地 通电时先打开保存箱电控箱上的电池开关 需长时间关机时 先拔掉电源再关掉此开关 保存箱每次开门时间尽量不超过1分钟 关门前如门封条上有冰水 建议擦拭干净 以保...

Page 3: ...products your Haier ULT freezer may be different from the ones illustrated in this manual and we do apologize for this User manuals are subject to change without notice This product is suitable for the ultra low temperature storage of products in applications such as clinical pharmaceutical scientific research and epidemic institutions It also can be used in blood stations hospitals centers for di...

Page 4: ...IOT board Optional screen Tricolor light IOT board Backup system control board Backup system sensor Optional touch screen Solenoid valve Electromagnet lock Electromagnet lock Backup system board Communication port for display board Magnetic proximity door switch Door ajar switch Cold chain Printer Tricolor light Optional Lithium battery Acid lead battery Battery switch Battery switch Battery Batte...

Page 5: ...the descriptions marked with the following labels Safety labels Haier Biomedical UK LTD Address Mytogen House 11 Browning Road Heathfield TN21 8DB United Kingdom Symbol for Manufacture R600a R1150 R600a R1150 Install padlock here for best security Wear cryo gloves to prevent frostbite 3 Refrigeration and Wiring Diagram Refrigeration diagram Suction Accumlator Capillary Tube Cascade Condenser Evapo...

Page 6: ... other methods should be considered in order to ensure safe working environments If there is a leakage of petroleum gas or other flammable gas close the gas supply valve and open doors and windows to ventilate the air Do not plug or unplug your freezer unit in order to avoid potential explosion or fire Only professional technicians or Haier service personnel can install the unit Failure to do so m...

Page 7: ...lug thereby causing electric shock and fire Should there be any malfunction in the equipment power off the unit and unplug the power cord from the power supply Continuous operation in an abnormal condition may result in electric shock and fire Never use gas lines water mains telephone lines or lightening rods as the grounding device for your Haier ULT unit This type of improper grounding may cause...

Page 8: ... on top of the unit or place any object on it Falling equipment may cause injury or property damage Do not use electrical appliances inside the chamber of the appliance unless they are of the type recommended by the manufacturer Optional Accessories When using the temperature recorder please refer to the User manual for Temperature Recorder provided with the recorder Temperature recorder The tempe...

Page 9: ...ration system During any repair operations gloves should be worn to prevent getting injured by sharp edges or corners Hold firmly onto the handle to close the door to avoid pinching your hands Do not tilt the unit more than 45 degrees when moving the unit The air filter for the condenser should be cleaned regularly A dirty filter could cause a malfunction or the freezer temperature to rise Do not ...

Page 10: ... the paint coating and plastic components Particularly never use gasoline or a solution with volatile chemicals to clean plastic or rubber parts Defrost the interior Frost and ice can form in between the door gasket and frame to form an air gap which can decrease the refrigeration effect of the unit Please use the provided plastic scraper to defrost the interior doors The following steps are how t...

Page 11: ...on before using the equipment If the socket is not grounded it must be connected to a grounded terminal by a qualified technician Installation Installation environment Installation site Do not ground the freezer through gas lines water mains telephone lines and lightning rods as this may lead to electric shock After installation the power plug must be easy to reach In case of emergency it is easy ...

Page 12: ...the battery sustains the temperature display If the battery voltage is insufficient the temperature display will turn off While the battery is still capable of providing power to the display the temperature display can be turned off by unplugging the power cord and turning off the battery control switch The freezer is also designed to auto adjust the inner temperature set point in high ambient tem...

Page 13: ...etwork system is in service Running indicator lamp is ON It means that the low temperature compressor is in service Backup system indicator lamp is ON It means that the backup refrigeration system is in service Alarm Alarm Status Code Instruction Buzzer Remarks High temperature alarm The current temperature the set one for high temperature alarm for 1 minute on end E00 The alarm lamp flashes ON an...

Page 14: ... recovery the unit can resume its operation based on the previous settings In the event of a power outage and recovery be sure to wait for at least 5 minutes before turning the unit on again to avoid damaging the compressors and refrigeration system If the freezer is not in use in an area without any supervision please make sure children will not approach the freezer and the doors should not be cl...

Page 15: ...r key to modify the set value of usb data reading cycle 3 T2 usb timing MM P2 01 12 DD P3 01 31 YYYY Pl 10 99 Hour P4 00 23 Minute P5 00 59 Press the or key to modify the timing of usb 4 P6 12 is the default value for USB derivative mode it is adjustable from 0 to 12 The data can be exported in different time frames with parameters of 0 12 among which 12 as default means exporting the data generat...

Page 16: ...play stops flashing which means the value set have been input into computer Otherwise the setting is invalid For example Set the inner temperature to 80 4 After setting the inner temperature the high temperature alarm and low temperature alarm will automatically adjust to proper values accordingly If user has special requirements follow the following steps to adjust the values manually Setting the...

Reviews: